Fire Magic E790I4EANW Benutzeranleitung

Seite von 38
37
TROUBLESHOOTING
If you have trouble with this Fire Magic
®
 grill, please use this list to identify the problem. By trying one or more of the solutions 
to the possible cause, you should be able to solve the problem. If this list does not cover your present problem, or if you have 
other technical diffi culties with the grill, please contact your local Fire Magic
®
 dealer or visit our web site at www.rhpeterson.com.
* Important:  Propane tanks  are equipped with a safety shutdown 
device that may cause low or no gas/fl ame at the 
burners if operating and lighting instructions are not 
followed exactly. If you suspect the propane tank  
safety shutoff is in effect, shut off all burner control 
valves  and the propane tank  valve . Then read and 
follow the LIGHTING INSTRUCTIONS exactly. 
Lighting instructions are located in your owner’s 
manual and printed on the grill’s metal drip tray. If the 
problem persists, continue troubleshooting, or contact 
your local dealer or R. H. Peterson for assistance.
PROBLEM
POSSIBLE CAUSE
CORRECTION
Accessories do
not operate
  1.  Power source not hooked to power supply
  2.  Master switch is off
  1.  Hook external power to grill.
  2.  Turn master switch on.
Ignition system 
failure
  1.  Power source not hooked to power supply
  2.  Improper air shutter adjustment
  3.  Ignition wire disconnected
  4.  Low gas pressure
5. Front carry-over port
6. Blown fuse in power supply box
7. Igniter malfunction
  1.  Hook external power to grill.
  2.  Adjust air shutters.
  3.  Plug wires back into ignition switches.
  4.  Have the gas co. check pressure at grill.
5. Clean burner ports.
 6. Replace the fuse. Reference the POWER SUPPLY 
FUSE REPLACEMENT section.
7. Contact dealer for replacement.
Insuffi cient heat
 1. Improper air shutter adjustment
 2. Using propane orifi ce for natural gas
 3. L o w   g a s   p r e s s u r e / f l a m e   ( p r o p a n e )
4. Low gas pressure/fl ame (natural)
 1. Adjust air shutters.
 2. Check/change orifi ces.
 3. Shut off all valves, including propane tank, and follow 
lighting instructions exactly. (See important note* 
below.)
 4. Have the gas co. check pressure at grill.
Uneven heating
  1.  Burner ports partially blocked by debris
  2.  Small spiders or insects in burner
  3.  Improper air shutter adjustment
  1.  Remove burners and clean out ports.
  2.  Inspect burners and orifi ces for spider webs or other debris 
that may block fl ow.
  3.  Adjust air shutter.
Thermometer not 
operating properly
 1. Thermometer 
malfunction
  1. Reset thermometer by turning master switch off then 
back on.
Interior & knob 
light(s) not operating
  1.  Thermometer light switch not functioning
  2.  Interior or knob light(s) burned out
  1. Reset thermometer by turning master switch off then 
back on.
  2.  Contact dealer for replacement.
Burner goes out on 
LOW
  1.  Valve "Low" setting needs adjustment
  1. Light burner on HIGH, immediately turn to LOW 
setting. Remove knob from valve and using a small fl at 
screwdriver, slowly turn the adjustment screw in the 
stem, a little at a time (30° to 45°), in either direction, 
until the fl ame is approximately 
1
/
4
" in height from 
burner ports.
Rotisserie noisy
  1.  Rotisserie out of balance
  1.  Adjust rotisserie counterbalance.
Rotisserie doesn’t
turn but lights work
  1.  Elec. socket circuit breaker is tripped
  1.  Reset circuit breaker (See Fig. 37-1).