Iron-A-Way AE42NDU Installationsanweisungen

Seite von 4
WARNING: TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING, WIRING OR SERVICING 
THIS PRODUCT.
All electrical work must be done in accordance with all applicable electrical codes.
NOTE:  Opening in the top of the ironing center cabinet 
electrical supply wire is located 2 1/4" on center from left side
for the of cabinet and 2 1/4" on center from the back of the
cabinet on all electrical models excepts UD-42.  The UD-42
supply wire is located 2 1/4" on center from the right side of
cabinet and 2 1/4" on center from the back of the cabinet.
SUPPLY LINE:  110 Volt / 15 Amps
   1. Open the front cover by removing the screw at the top and bottom of the electrical wireway.
NOTE:  In the front cover of the electrical wireway, near the top, there is a loose black and a loose white wire
pigtail that are provided for hookup to the electrical supply line.
   2. Locate and remove the knockout at the top of the back cover of the electrical wireway and install a 3/8" romex
connector where the knockout was removed.
   3. Verify that there is ample supply wire available to run from the top of the ironing center cabinet to the approximate
location of the electrical pigtails.  (A free wire length of approximately 48" is recommended.)
   4. Begin to place the ironing center into its location while feeding the free supply wire through the opening in the 
top of the ironing center cabinet and the 3/8" romex connector attached to the back cover of the electrical
wireway.  (If surface mounting, a vent hole will need to come through the back of the cabinet for electrical 
feed of wire.  Approximate center diameter position of electrical knockout is 24 1/2" down from top left of 
cabinet and 2 13/16" from left side of cabinet.
   5. Put into place and secure the ironing center cabinet as identified in Step 8 through 13 of the Recessed Mounting
or Step 9 through 13 of Surface Mounting whichever mounting method is applicable.
   6. Connect all power supply wires and ground wires in accordance with all electrical codes.  Trim as necessary
excess supply wire.  
   7. Place into position the top cover of the electrical wireway making sure no wires are pinched when reinstalling
the top cover to the back cover.  Reinstall the top screw and bottom screw removed in Step 1 into the
electrical wire cover.
   8. Turn on power at Service Entrance to test and verify that electrical components (timer, automatic disconnect
switch, electrical outlet) are working properly.
220 West Jackson
Morton, IL  61550-1551
Bus:  (309) 266-7232
Fax:  (309) 266-5088
001072  02/15
www.ironaway.com
ELECTRICAL INSTRUCTIONS
Built-In Ironing Centers 
"A space saving built-in convenience"