Planning the Installation
Cabinet Layout
• 
Carefully check the location where the range is to be 
installed. For best performance, the range should be placed 
away from drafts that may be caused by doors, windows and 
heating and air conditioning outlets.
• 
To reduce the risk of personal injury and to reduce 
accumulated smoke in the room, Dacor strongly recommends 
installing a range hood. A range hood should project 
horizontally a minimum of 5 inches beyond the face of the 
cabinets.
• 
All maximum and minimum dimensions and clearances 
shown in the diagrams below must be maintained for safe 
operation.
• 
The range may be installed flush to the rear wall. Dacor 
strongly recommends installing a non-combustible material 
on the rear wall above the range and up to the vent hood or 
installation of a backguard. It is not necessary to install non-
combustible materials behind the range below the countertop 
height.
• 
Any openings in the wall behind the appliance or in the floor 
underneath it must be sealed.
Gas and Electrical Service
• 
The shaded area shown denotes the suggested location of 
the gas inlet and the electrical junction box/receptacle. For 
replacement purposes, the location of the existing utilities 
may be utilized provided they do not interfere with the 
sides or rear of the range. Check local building codes for 
permissible gas valve locations.
• 
An external manual shut-off valve must be installed between 
the gas inlet and the range, for the purpose of turning on or 
shutting off gas to the appliance.
The installation must allow for the following:
• 
Access to the gas shut-off valve when the unit is installed.
• 
Access to the remote circuit breaker panel/fuse box, when the 
range is in place.
• 
The gas supply piping and shut-off valve, and the electrical 
junction box/receptacle must be located so they do not 
interfere with the range when it is installed.
• 
The junction box and gas shut off valve must be located 
so that the range can be pulled out for service while the 
appliance remains connected.
Note 2
F
G
2
 Cabinet/countertop depth is at discretion of customer but 
cabinet face MUST NOT protrude further than rear of front 
panel, see product dimensions.
3
 Vertical distance from range top panel level.
1
 Vertical to combustible surface from range grate level; if 
installing an overhead vent hood, also check the hood 
specifications for minimum required clearances. 
Non-combustible 
surface along 
back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2  cm)
min.
1
36 1/2” 
(92.7 cm)
max.
13” (33.0 cm)
max.
4
18” (45.7 cm)
min.
3, 4
Suggested 
location of 
utilities
 
3
4
 This specification does not apply for cabinets more 
than a horizontal distance of 10” (25.4 cm) from the 
edge of the range.
G
10" (25.4 cm) min.
to combustible side
walls above the range
(both sides)
non-combustible
Minumum  Countertop Height:
30 1/4” (76.8 cm) 
Maximum  Countertop Height:
36 1/2” (92.7 cm)
rear wall recommended
Backsplash
3/8" (1.0 cm)
Min. flat countertop
overhang
H
2 13/16"
(7.1 cm)
Note 2
Cutout tolerances: +1/16” (+1.6 mm), -0 
unless otherwise stated
CUTOUT DIMENSIONS
Range Model
F
G
H
ER36D
42” (106.7 cm)* 
36” (91.4 cm)**
36 1/16” 
(91.6 cm)**
33 1/2” 
(84.8 cm)
ER48D
54” (137.2 cm)* 
48” (121.9 cm)**
48 1/16” 
(122.1 cm)**
43 1/2” 
(110.2 cm)
* Recommended ** Minimum
APPROVED DOWNDRAFT MODEL NUMBERS
Range Model
Downdraft Vent Model
ER36D
ERV36-ER
ER48D
ERV48-ER
Standard Cutout with 
Range Hood
Cutout with Optional Downdraft Vent 
(Top View)
IMPORTANT: See the downdraft installation instructions 
for the duct and electrical installation requirements. Use 
only the downdraft vent models specified above.