Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61 cm) base cabinet depth and 
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 
cabinet is protected by not less than 
¹⁄₄" (0.64 cm) flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an unprotected wood or metal 
cabinet.
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Check with a qualified electrical installer if you are not sure the 
range is properly grounded.
This range must be connected to a grounded metal, permanent 
wiring system.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.
A copy of the above code standards can be obtained from:
 National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located below 
the electronic control on oven frame. See the following 
illustration.
Models rated from 12.7 kW at 240 volts (9.5 at 208 volts) 
require a separate 50-amp circuit.
A circuit breaker is recommended.
Flexible conduit from appliance should be connected directly 
to the junction box.
Do not cut the conduit. The length of conduit provided is for 
serviceability of the range.
A UL listed or CSA approved conduit connector must be 
provided.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the ends of the 
flexible conduit leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
A. 13" (33 cm) upper cabinet 
depth
B. 30" (76.2 cm) min. opening 
width
C. For minimum clearance to the 
top of the cooktop,
see NOTE*.
D. 23
¹⁄₄" (58.1 cm) opening 
depth
E. 30" (76.2 cm) min. opening 
width
F. Junction box - 5.5" (14 cm) 
min. from either cabinet, 
8
¹⁄₄" (21 cm) max. from floor
G. Cabinet door or hinge should 
not extend into cutout.
H. 27
¹⁄₂" (69.9 cm) top of 
countertop to support slats
I. 6" (15.2 cm) wide support slat 
on each side of cutout
A
B
C
D
E
F
G
H
I
A. Model/serial number plate
  
A