Electrical Service Installation
 wArning
The electric service to the range hood should be installed 
only by a licensed electrician.
Install a junction box in the vicinity of the hood electri-
cal access holes according to local codes. Install it either 
behind or above the hood. The diagram below shows sug-
gested locations.
Drill 7/8” holes in the wall or cabinet as necessary to allow 
the wiring to pass through into the hood. See page 4 for 
hole locations.
Duct Cutout
Using a pencil, draw the vertical center line for the 
1. 
range hood on the wall. Extend the line down 10” (25.4 
cm) from where the top of the hood will be located. 
The center line for the hood is usually halfway between 
the cabinets at the installation location or the same as 
the center line of the cooktop or range. The line will be 
used to line up the mounting brackets during installa-
tion.
Locate the center lines for the duct cutout(s) according 
2. 
to the dimensions on page 4. For installations venting 
through the top of the hood, use the top dimensions to 
locate the center lines on the ceiling or cabinet bottom. 
For installations venting through the back of the hood, 
use the back dimensions to locate the center lines on 
the back wall. See the diagrams on the right.
Cut a hole for the duct to pass through 11” (28 cm) in 
3. 
diameter. Center it on the center lines. Dual exhaust 
models require two (2) holes.
Preparing for Installation
Verify the Package Contents
Unpack the parts box and verify that all parts have been 
included according to the parts list on page 5. If any item 
is missing or damaged, please contact the dealer immedi-
ately. Do not install a damaged or incomplete appliance.
Make sure you have everything necessary for proper instal-
lation before proceeding.
Mounting Location Preparation
 wArning
The electrical service to the range hood should be 
installed only by a licensed electrician.
Observe all governing codes and ordinances during 
site preparation and installation. Contact your local 
building department for further information.
Failure to properly anchor the hood to the wall may 
result in personal injury due to the unit falling off the 
wall.
To avoid an electric shock hazard and property dam-
age, locate electric wires and water pipes and avoid 
drilling or cutting in the vicinity.
Use the temporary mounting brackets only to hold 
the hood in place until permanent anchoring is 
installed.
Temporary mounting brackets, and the 
screws and anchors to hold them in place 
during installation are provided with the 
hood. Two anchors and screws are used 
per bracket.
Determine the number, size and type of 
anchors required to attach the hood permanently to the 
wall and/or the cabinets based on the type of installa-
tion and the weight chart on page 3.
Make sure the mount-
ing surface is properly 
reinforced to handle the 
full weight of the hood. 
If mounting the unit to a 
drywall or plastered sur-
face, install a reinforced 
mounting block between 
the studs behind all hood 
mounting locations. You 
may attach screws directly 
to the studs and cabinets 
if they line up with the 
mounting holes in the back 
and top of the hood. If 
mounting the hood to brick 
or masonry, select anchors 
capable of holding the full 
weight of the hood.
Suggested
Electrical
Location
Hood
Location