Planning the Installation
System Layout
The vent system consists of the raised vent itself and a 
remote blower. You must install a Dacor model REMP3 
or REMP16 remote blower for the raised vent to oper-
ate properly. For directions on installing the remote 
blower, see the REMP3/16 installation instructions.
 WARNING
Failure to install a remote blower or proper duct 
work may result in a back draft and/or the insufficient 
venting of smoke and fumes.
To reduce the risk of personal injury caused by 
reaching over a hot appliance, cabinet storage 
space located directly above the range should be 
avoided.
Do not store combustible materials or items adverse-
ly affected by heat in cabinet areas above the appli-
ance.
Follow the instructions and diagrams for minimum 
safe clearances and installation location. Failure to 
do so may result in a fire or safety hazard.
Wire the remote blower to turn on when the raised vent 
is turned on by running a piece of conduit parallel to 
the duct work and connecting it to the raised vent on 
one end and the remote blower on the other. There are 
7/8” access holes in the bottom and side of the raised 
vent for connecting the conduit.
The raised vent exhaust may be configured to vent 
through the back, the bottom or through one of the 
sides. The maximum allowable duct run must be taken 
into consideration when determining the layout. See 
Planning the Duct Work for further details.
 WARNING
Observe all governing codes and ordinances during 
planning and installation. Contact your local building 
department for further information.
The electric outlet for the raised vent should be 
installed only by a licensed electrician.
Electrical Specifications
The raised vent is supplied with a 28” (711 mm) power 
cord terminated by a three-prong plug. Plug it directly into a 
dedicated, grounded, three prong, electrical outlet. Do not 
use an extension cord.
The correct voltage, frequency and amperage must be sup-
plied to the electrical outlet from a grounded, single phase 
circuit that is protected by a properly sized circuit breaker 
or time-delay fuse.
Electrical Supply Requirements
A 3 prong electrical outlet connected to a 120 Vac, 60 
Hz, 15 Amp. grounded, dedicated circuit is required.
The customer must supply conduit with minimum 
current carrying capacity of 8 Amps to supply power 
to the remote blower from the raised vent. See 
Planning the Duct Work for further details.
The above specifications are for reference only. If the 
power supply requirements shown above do not agree 
with those listed on the appliance data label, use the 
required voltage, frequency and amperage ratings on 
the appliance data label.
It is the owner’s responsibility to ensure that electrical 
outlet is installed by a licensed electrician. The electri-
cal installation must comply with the latest revision of 
the National Electric Code ANSI/NFPA 70 (latest revi-
sion) and local codes and ordinances.
If the electrical service provided does not meet the 
product specification, or does not conform to the NEC 
or local standards, do not proceed with the installation. 
Call a licensed electrician to correct the electrical ser-
vice before proceeding.
Locate the electrical outlet in an accessible location, 
so that the power plug can be disconnected for service 
without removing the raised vent or the range from the 
cabinet.