BlueStar BSMLSS58SS Installationsanweisungen

Seite von 20
1. Install three wires: black, white and green (#16  AWG) in 1/2" conduit from the service panel to the hood junction box.
Power supply must be rated for 120v, 60Hz, 15 amps (minimum).
Remove junction box and selected knockout.  Then install the strain-relief (conduit) connector in the removable
back panel.  For PMLSS-28” & 34” run power line through single knockout at top and route to junction box
mounted on back.
Remove the junction box from the removable back panel.  Connect black wire to power-supply black wire, white wire
to power-supply white wire, and green wire to power-supply green wire.
Place all wiring connectors inside junction box and re-install on removable back panel.
2.
3.
4. 
2-1/2"
2-1/2"
2"
Knock Out Holes Location
MLSS - 40” to 70” wide
PMLSS - 40” to 70” wide
3"
Knock Out Location
CMLSS
Knock Out Holes Location
10"
3-3/4"
2 "
Knock Out Holes Location
MLSS - 28” to 34” wide
PMLSS - 28” to 34” wide
3"
2-1/2"
2-1/2"
2"
3"
Knock Out Holes Location
MLFS
2-1/2"
2-1/2"
2"
ELECTRICAL  CONNECTIONS
7
Figure 6-A.
Figure 6-C.
Figure 6-D.
Figure 6-B.