Installation preparation
9
CAUTION
Ensure that there are no electric wires, gas or 
water pipes in the area where holes are to be 
made.
Check wall
The walls must be smooth, vertical, and sufficiently 
load-bearing.
The depth of the bore holes must be the same 
length as the screws. The wall plugs must have a 
secure grip.
Suitable fasteners must be used for other 
structures, such as plasterboard, porous concrete, 
and poroton bricks.
The max. weight of the appliance is 
7 kg
.
Only specialist personnel may create the required 
wall breakthrough. The building support structure 
must remain in place.
Risk of damage caused by returning condensate. 
Install the wall breakthrough with a slight outward 
gradient (1° downward slope). 
Electrical connection
9
WARNING
Risk of electric shock
Parts inside the appliance can have sharp edges. 
The connection cable can be damaged. Do not 
bend or pinch connection cables during 
installation.
The required connection information is on the 
appliance's identification plate.
This appliance meets EC radio interference 
suppression requirements.
This appliance may only be connected to a correctly 
installed grounded socket.
Fit the grounded socket in close proximity to the 
appliance.
The grounded socket should be connected via its 
own circuit.
If the grounded socket is no longer accessible after 
installing the appliance, an all-pole isolating switch 
(e.g. circuit breaker, fuses and contactors) with at 
least a 3 mm contact gap must be included in the 
installation.