Gaggenau AR401742 Installationsanleitung

Seite von 36
9
Connect appliance
Note: The control unit must be mounted indoors in an 
easy-to-reach location.
1
Fit the plug onto the mains cable. Secure the blue 
wire in connection N, the brown wire in connection 
L, and the green/yellow wire in the central 
connection. Fit the connector parts. Tighten two 
screws for the strain relief. 
2
Firmly insert the mains cable and control cable from 
the remote fan unit into the control unit. 
3
Firmly insert the network cable from the control unit 
to the extractor hood. The plug must snap into 
place.
Note: The X1 and X2 connection sockets are 
identical.
4
Connect the control unit to the mains and check 
that it works correctly. If the appliance does not 
work, check that the connection cable is positioned 
correctly.
Additional switching output
Work must only be carried out on the additional  
switching output by a qualified electrician in 
accordance  with the country-specific requirements and 
standards.
The appliance has an additional switching output  X16 
(potential-free contact) that can be used to connect 
other appliances,  such as a ventilation system that is 
available at the installation site. The contact is closed 
when the fan is switched on, and is opened when  the 
fan is switched off.
The switching output is located under   a cover. Maximum 
switching power 30 V/1 A (AC/DC). The signal that is  
connected to the contact must correspond to class of 
protection 3.
;;
;
;;
;