Whirlpool WOD93EC0AE Installationsanweisungen

Seite von 32
5
Electrical Requirements
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and the wire gauge are in accordance with local 
codes.
Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.
This oven must be connected to a grounded metal, permanent 
wiring system.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical Connection
To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located under 
the control panel on single ovens and under the control panel 
on the upper oven cavity on double ovens. See the following 
illustrations.
Models rated from 7.3 to 9 kW at 240 volts (5.4 to 7.4 kW at 
208 volts) require a separate 40-amp circuit. Models rated at 
4.8 kW and below at 240 volts (3.6 kW and below at 
208 volts) require a separate 20-amp circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused 
disconnect) through flexible, armored or nonmetallic 
sheathed, copper cable (with grounding wire). See “Make 
Electrical Connection” section. 
Flexible conduit from the oven should be connected directly 
to the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.
A UL listed or CSA approved conduit connector must be 
provided.
If the house has aluminum wiring, follow the procedure 
below:
1. Connect a section of solid copper wire to the ends of the 
flexible conduit leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
For power requirements for models WOS51EC7A, WOS51EC0A, 
WOD51EC7A, WOD51EC0A, WOS92EC7A, WOS92EC0A, 
WOD93EC7A, WOD93EC0A, MEW7527A, MEW7530A, 
MEW7627A, MEW7630A, MEW9537A, MEW9627A, MEW9530A 
and MEW9630A, refer to the following table.
For power requirements for models KEBK171B, KEBK101B, 
KEBK276B, KEBK206B, KEBS179B, KEBS109B, KEBS277B, 
KEBS279B, KEBS207B and KEBS209B, refer to the following 
table.
For power requirements for models KEBU109B and KEBU209B, 
refer to the following table.
Single Oven
A. Model/serial number plate
Double Oven
A. Model/serial number plate
A
A
Voltage
Single 
Thermal
Single 
Convect
Double 
Thermal
Double 
Convect
240 VAC
3690 W
3720 W
7370 W
7400 W
208 VAC
2790 W
2820 W
5580 W
5610 W
240 VAC
15.4 A
15.5 A
30.7 A
30.8 A
208 VAC
13.4 A
13.6 A
26.8 A
27.0 A
Voltage
Single 
Thermal
Single 
Convect
Double 
Thermal
Double 
Convect
240 VAC
4090 W
4120 W
8170 W
8200 W
208 VAC
3099 W
3122 W
6190 W
6212 W
240 VAC
17.1 A
17.2 A
34.1 A
34.2 A
208 VAC
14.9 A
15.0 A
29.8 A
29.9 A
Voltage
Single Convect
Double Convect
240 VAC
5420 W
9500 W
208 VAC
4106 W
7197 W
240 VAC
22.6 A
39.6 A
208 VAC
19.8 A
34.6 A