Clearance Dimensions 
(Wood/Composite Overlay)
10
The bottom of a standard hood should be
30” (76.2 cm) min. to 36” (91.4 cm) max.
above the countertop. This would typically
result in the bottom of the hood being
66” (167.6 cm) to 72” (182.9 cm) above the
floor. Refer to the range hood installation
instructions for additional information.
These dimensions provide for safe and
efficient operation of the hood.
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
30”
(76.2 cm)
6”
(15.2 cm)
Wood/Composite 
Overlay
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
66”min.
(167.6 cm)
to
72”max.
(182.9 cm)
24”
(61.0 cm)
or
27”
(38.6 cm)
Wood/Composite 
Overlay
0”
 
(
0 cm)
30”min.
(76.2 cm)
to
36”max.
(91.4 cm)
Note: Minimum clearance for back wall
is 0” with backguard or high-shelf. See
Standoff Bracket Removal section to
allow 0” clearance.
Island Installation
Wall Installation
Important: This range comes standard
with an Island Trim. There must be a
minimum of 6” (15.2 cm) clearance from
rear of range to a combustible wall.
Clearances from non-combustible
materials are not part of the ANSI Z21.1
scope and are not certified by CSA.
Clearances to non-combustible materials
must be approved by the authority having
jurisdiction.