Whirlpool WOS92EC0AH Datenbogen

Seite von 8
3
Approved Built-In Oven and Gas Cooktop Combinations
For the approved model number combinations, refer to the undercounter label located on top of the oven chassis.
NOTE: For undercounter installation, it is recommended that the junction box for oven be located in the adjacent right or left cabinet. A 
1" (2.5 cm) minimum diameter hole should have been drilled in the upper rear right or left corner of the side wall surface to pass the 
appliance cable through to the junction box.
The upper shaded areas are recommended locations for recessed junction box for 120-volt grounded outlet for cooktop.
Lower shaded areas are recommended locations for flexible or rigid gas pipe installation. The gas connection on the cooktop is on the 
right (same location as “J” in the above diagram). The gas pipe can be installed on either side of the cutout, and either through the floor 
or through the wall. Refer to local codes regarding the use of gas lines.
A. 24" (61 cm) cabinet depth
B. 1" (2.5 cm) clearance to bottom of countertop
C. 25" (63.5 cm) countertop depth
D. Recommended oven junction box locations
E. 1" (2.5 cm) clearance to cabinet
F. 27¾" (70.5 cm) minimum cutout height
G. Allow 
⁵⁄₈" (1.6 cm) for oven trim to overlap on each side.
H. 36" (91.4 cm) from cabinet base to countertop
I. 31
³⁄₈
" (79.7 cm) from top of countertop to bottom of cutout
J. Gas line through wall 10
¹⁄₂" (26.7 cm) to center of cutout
K. 3¼" (8.3 cm)
L. Gas line through floor 10½" (26.7 cm) to center of cutout
M. 3½" (8.9 cm)
N. 4
⁵⁄₈" (11.7 cm) maximum from cabinet base
O. See Cutout Dimensions chart.
CUTOUT DIMENSIONS
Oven Size
Oven Cutout Dimension
24" (61 cm)
22
¹⁄₂" (57.2 cm)
27" (68.6 cm)
25
¹⁄₂" (64.8 cm)
30" (76.2 cm)
28½" (72.4 cm)
36" (91.4 cm)
34
¹⁄₂" (87.6 cm)
A
C
D
E
F
G
H
N
M
E
D
K
B
J
L
O
I