Dacor DCT305BLP Installationsanweisungen

Seite von 16
6
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space 
behind raised vent 
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV3615 raised vent.
Check raised vent 
dimensions/specifications 
to determine proper fit
 DCT365 cooktop
Side View - DCT365 Cooktop with ERV3615 Raised Vent
4 1/4” (10.8 cm) min. 
from mounting surface to 
combustibles below
cooktop chassis
E
F
C
D
Minimum distance to combustible side 
wall above countertop (both sides)
F
Vertical
combustible
surface
Rear
wall
1 5/8” min.
(4.1 cm)
Countertop Cutout Dimensions
Installation Type
(C) Minimum
(D)
(E)
(F) Minimum
DCT305*
3 1/4” (8.3 cm)
19 5/8” (49.9 cm)
27 5/8” (85.4 cm)
6 7/8” (17.5 cm)
DCT365 with no raised vent
3 1/4” (8.3 cm)
19 5/8” (49.9 cm)
33 5/8” (85.4 cm)
6 7/8” (17.5 cm)
DCT365 with ERV3615 raised vent
3/8” (1.0 cm)
22 3/4” (57.8 cm)
33 5/8” (85.4 cm)
6 7/8” (17.5 cm)
  * Model DCT305 is not compatible with a raised vent
Installation Specifications
Cutout Dimensions
All tolerances +1/16” -0 (+1.6 mm, 0) unless otherwise noted.