Liebherr RO510 Designanleitung
21
The given cabinet opening height dimension includes 2"
for ventilation.
for ventilation.
If the appliance will be vetilated above the cabinet or in a
soffit, the height dimension can be adjusted accordingly.
soffit, the height dimension can be adjusted accordingly.
IMPORTANT
Minimum ventilation opening is 46 sq in !
Cabinet Opening Dimensions
The power cord exits
the rear of the appli-
ance at this location.
the rear of the appli-
ance at this location.
Free length of the
power cord is 90".
power cord is 90".
The electrical
outlet must not be
situated behind
the appliance and
must be easily
accessible.
outlet must not be
situated behind
the appliance and
must be easily
accessible.
With a cabinet depth of 27", the front of the appliance
housing is flush with the cabinet frame. (see chapter
"Appliance Dimensions Top View")
housing is flush with the cabinet frame. (see chapter
"Appliance Dimensions Top View")
Side by Side WS 17800
To avoid condensation on the side walls at side by side
applications a minimum distance of 2" between the
appliances is required.
applications a minimum distance of 2" between the
appliances is required.
Wine and Undercounter
Optional venting 46 square inches