Electrical Requirements & Safety
A 15 amp or 20 amp, 110-120 VAC, circuit which is 
grounded and protected by a circuit breaker or fuse is 
required. 
We recommend using a dedicated circuit for each 
appliance to prevent circuit overload and the chance of 
interruption to the appliance.
The appliances are equipped with a three-prong 
(grounding) polarized plug for protection against possible 
shock hazards. 
Comply with the National Electrical Code as well 
as local codes and ordinances when installing the 
receptacle.  
 
 WARNING! 
Electrocution hazard.
Electrical grounding required. 
  Do not remove the round grounding 
prong from the plug. 
  Do not use extension cords or 
ungrounded (two-prong) adapters.
•  Do not use a power cord that is frayed or
damaged.
•  
Do not use a power strip. 
Failure to follow these instructions may 
result in fire, electrical shock or death.
Additional Electrical Requirements for Outdoor 
Refrigerator RO 510
When using the RO 510 Appliance Indoors
Connect the appliance to a 15 amp or 20 amp, 110-
120 VAC, circuit which is grounded and protected by a 
circuit breaker or fuse.
When using the RO 510 Appliance Outdoors
The appliance must be connected to a GFCI (Ground 
Fault Circuit Interrupter) receptacle.
 
 WARNING! 
Electrocution hazard.
For outdoor use, connect this appliance to 
a GFCI receptacle only.
Failure to follow these instructions may 
result in fire, electrical shock or death.
IMPORTANT
Do not place the appliance where it may be in 
standing water or where the power cord may be 
immersed.