Summit WMC64P Servicehandbuch

Seite von 38
Service manual WM70.C
10
1 Service
11 Info
SP: XXXX
Date the software was programmed (Year_Week)
CM: XXXX
Date of manufacture of the control unit (Year_Week)
SW:
Software version
SW:
Software version
NC:
Number of cycles/programmes run
NC 1:
Number of cycles for Programme 1
NC 2:
Number of cycles for Programme 2
NC 28:
Number of cycles for Programme 28
12 Fault 
scenarios
Fault 1
Shows current fault. The display shows Fault name_Programme 
number_Number of cycles_ Index number.
Example: Thermistor fault_Pr5_9_(1)
Fault 2
Fault 3
13 
Diagnostics
Test
Test valve 1
Inlet valve 1 is open.
Test valve 2
Inlet valve 2 is open.
Test valve SM Inlet valve 1 and 2 are open.
Test valve 3 
Inlet valve 3 is open.
Test heater
Heater on up to max. 60°C.
Test motor
The motor normally runs at 49 rpm.
Test drain
The drainage pump runs.
Test spin
The machine runs a spin sequence, the drainage pump runs.
Test door
The door lock is activated and the door opens. Returns to the 
programme menu.
14 Total 
reset
The machine is restored to its factory settings. Returns to the 
programme menu after Total reset.
15 ABC 
reset
The custom programmes (Pr20-Pr22) are reset. Returns to the 
programme menu after ABC reset.
Return
Press the Key button (S5) to return to 1 Service.
Service menu content