Summit WMC64P Servicehandbuch

Seite von 38
Service manual WM70.C
22
Wiring diagram WM70.C
This document must not be copied without
our written pemission, and the contents
thereof must not be imparted to a third party
nor be used for any unauthorized purpose.
Contravention will be prosecuted.
Asko Appliance AB
CIRCUIT DIAGRAM WM70.C
80 886 19 - 00
WIRES IN ALL MACHINES
INTERNAL CONNECTION
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITHIN +/-10% ARE REGARDED AS NORMAL COMPONENT
      F: RADIO INTERFERENCE SUPPRESSION FILTER    680K Ohm
    EL: HEATING ELEMENT                                                       25 Ohm
    AP: DRAIN PUMP 50 Hz                                                        144 Ohm
    AP: DRAIN PUMP 60 Hz                                                          76 Ohm
    AV: DRAIN VALVE                                                          110/134 Ohm
    LL: DOOR LOCK, 1-2                                                            122 Ohm
 NTC: THERMISTOR                                                       6.1 - 3.8 K Ohm
  IV 1: INLET VALVE 1                                                             3.7 K Ohm
  IV 2: INLET VALVE 2                                                             3.7 K Ohm
   IV3: INLET VLAVE 3                                                             3.5 K Ohm
  MO: MOTOR, 1-3                                                              4,3±7% Ohm
                         1-2                                                              4,3±7% Ohm
                         2-3                                                              4,3±7% Ohm
MCU: MOTOR CONTROL UNIT
     N: PRESSURE SWITCH
   TS: PRESSURE SENSOR
TG: TACHO GENERATOR
   BA: CONTAINER
INKB: INCOMING GROUND
    CI: COMMUNICATIONS INTERFACE
IV2
IV1
NTC
F
TS
AP/AV
LL
MO
MCU
3
2
1
CABLE POSITIONS
  1: MOTOR COMMUNICATION
  2: THERMISTOR
  3: INLET VALVES
  4: DOOR LOCK, DRAIN PUMP, PREASSURE SWITCH
  6:
COMMUNICATION
INTERFACE
  7: COIN COLLECTOR
  8: POWER
  9: HEATING ELEMENT, PREASSURE SWITCH
10: MOTOR POWER
3
1
2
TG
S1
S4 S5
<N
N14
N12
N16
N11
E
L
1
F
3
1
N
R
4
3
R
4
4
R
3
4
R
3
3
R
2
3
R
2
4
R
A
R
B
EL
INKB
BA
N
L2
L3
L1
R33
R43
E
L
2
F
2
1
F
B2
F2
F3
B3
R23
IV3
AV
BO
WIRES IN SOME MACHINES
CI
WIRING WITH
COINMETER
BLACK
B1
B2
BROWN
B5
B4
B3
YELLOW-
GREEN
BLUE
B6
BLACK
BLUE
B2
B1
B6
B5
B4
B3
WIRING WITHOUT
COINMETER
B1
B4
B6
CI
N
L1
R33
B2/F21
B6
F1
F2
F1
F21
F22
F31
F32
F22/32
F2
INKB
F31
1 Phase, 16 A
N
L1
R33
B2
B6
F1
F22/32
F2
INKB
F21
1 Phase, 10 A
3 Phase, 10A
B
5
2010-05-20
SERVICE MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S4
TURN ON POWER (S1)
PRESS S4 5 TIMES TO ENTER SERVICE MENU
PRESS DOOR OPENING (S5) TO CHANGE MENU STEP
ROTATE DIAL TO CHANGE IN STEP
PRESSING START/STOP (S4) STORES AND EXITS SERVICE MENU
USER SETTINGS MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S5
TURN ON POWER (S1)
PRESS S5 5 TIMES TO ENTER MENU