BlueStar RNB486GV2LP Installationsanweisungen

Seite von 14
13 
 
ELECTRICAL CONNECTIONS 
1.  The installation of this appliance must conform with all applicable local codes.    In the absence of local 
codes, the installation must conform to the latest level of the National Electric Code, and ANSI/NFPA 70. 
2.  This appliance is equipped with a standard three prong polarized, NEMA 5-15P line cord to be plugged 
into a 120 Volt 15 AMP outlet. 
3.  Removing the grounding prong from the plug will void the manufacturer’s warranty. 
4.  The cord exits the appliance at the lower rear toward the right (viewed from front) side. 
5.  If the electrical supply is not turned on or is interrupted, the appliance will not operate. 
6.  The applicable wiring diagram for this appliance is affixed to the appliance. 
7.  The circuit where you plug your appliance must be grounded and polarized. 
8.  We recommend the circuit for your appliance be a non-GCFI dedicated line. 
9.  It is recommended that your circuit never include a microwave oven. 
 
SERVICE 
If the appliance requires service, to gain access to control valves or switches behind front control panel please 
follow the below steps: 
  Remove knobs. 
  Remove screws attaching control panel to base structure located under the top grates. 
  Remove screw from each bottom end of control panel. 
  Pull control panel forward to remove. 
 
REPLACEMENT PARTS 
  Replacement Parts can be acquired by calling Customer Service at 1-800-449-8691 or Fax (610) 
376-2596.     
 
 
WARNING 
This appliance is equipped with a three-pronged grounding plug for your protection against shock hazard 
and  should  be  plugged  directly  into  a  properly  grounded  receptacle.    Do  NOT  cut  or  remove  the 
grounding prong from this plug.    If the appliance is not grounded or its polarity is reversed, severe shock 
hazards can exist. 
 
 
VENTILATION 
Proper ventilation is highly important for good operation.    This appliance must be installed under a ventilation 
hood.    We recommend that the hood should be six inches [150 mm] wider than the appliance, however, it is not a 
requirement. 
 
A strong exhaust fan can create a vacuum in the room.    For proper air balance, work with your dealer and/or 
contactor to properly size your hood and its exhaust fan.    It is recommended that your exhaust hood be powerful 
enough to move a minimum of 300 cfm. 
 
IMPORTANT 
ALL  GAS BURNERS NEED SUFFICIENT AIR TO OPERATE  AND LARGE OBJECTS SHOULD NOT BE PLACED IN 
FRONT  OF  THIS  APPLIANCE  WHICH  WOULD  OBSTRUCT  THE  AIR  FLOW  THROUGH  THE  FRONT.    OBJECTS 
SHOULD NOT BE PLACED ON THE REAR BACKGUARD WHILE IN USE.    THIS COULD OBSTRUCT THE VENTING 
SYSTEM OF THE OVEN’S FLUE PRODUCTS.