Parts needed:
Check local codes. Check existing electrical supply and venting, 
and read “Electrical Requirements” and “Venting Requirements” 
before purchasing parts.
Mobile home installations require metal exhaust system 
hardware, available for purchase from the dealer from whom  
you purchased your dryer. For further information, please 
reference the “Assistance or Service” section of the “Use and 
Care Guide.”
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:
 
A UL listed 30-amp power supply cord, rated 120/240 volt 
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to the  
dryer must end in ring terminals or spade terminals with 
upturned ends.
 
A UL listed strain relief.
Location Requirements
You will need:
 
A location allowing for proper exhaust installation.  
See “Venting Requirements.”
 
A separate 30 amp circuit.
 
If you are using power supply cord, a grounded electrical 
outlet located within 2 ft. (610 mm) of either side of dryer.  
See “Electrical Requirements.”
 
A sturdy floor to support the total weight (dryer and load) 
of 200 lbs. (90.7 kg). The combined weight of a companion 
appliance should also be considered.
 
Level floor with maximum slope of 1" (25 mm) under entire 
dryer. (If slope is greater than 1" [25 mm], install Extended  
Dryer Feet Kit, Part Number 279810.) If not level, clothes  
may not tumble properly and automatic sensor cycles may  
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Installation clearances:
The location must be large enough to allow the dryer door  
to open fully.
 
Dryer Dimensions
A. Wide opening side-swing door
B. Wide opening hamper door
*Most installations require a minimum 5½" (140 mm) clearance   
 behind the dryer for the exhaust vent with elbow. See “Venting  
 Requirements.”
Minimum spacing for recessed area or  
closet installation
The dimensions shown following are for the minimum spacing 
allowed.
 
Additional spacing should be considered for ease of 
installation and servicing.
 
Additional clearances might be required for wall, door, and 
floor moldings.
 
Additional spacing of 1" (25 mm) on all sides of the dryer is 
recommended to reduce noise transfer.
 
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required.  
Louvered doors with equivalent ventilation openings  
are acceptable.
 
Companion appliance spacing should also be considered.
Minimum Required Spacing
 
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
27"
(686 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356  mm)
 
  29
½"
(749 mm)
   
5
½"*
 (140 mm)
  48 in.
  
(310 cm )
2
*
2
  
24 in.
(155 cm )
*
2
       
3"*
(76 mm)
       
3"*
(76 mm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
22
3
/
4
"
(578 mm)
29
1
/
2
"
(749 mm)
13
3
/
4
"
(349 mm)
29
1
/
2
"
(749 mm)
27"
(686 mm)
1
1
/
2
"
(38 mm)
43"
(1092 mm)
A
B