DISPLAY PANEL 
• 
Displays the set humidity level (from 35% to 85%) or auto-start/stop time (0-24) while 
setting, then returns to display actual room humidity level (±5% accuracy), in a range of 30% 
RH to 90%RH (relative humidity). 
• 
Displays error codes and protection codes: 
AS – Humidity sensor error. Unplug and plug back in. If error repeats, call for service. 
ES – Temperature sensor error. Unplug and plug back in. If error repeats, call for 
service. 
P2 – Bucket is full. Empty bucket and replace. 
EC – Unit malfunction. Please make sure the environment temperature is suitable for 
operation.  
E3 – Unit malfunction. Unplug the unit and plug back in. If error repeats, call for service. 
Eb – Bucket is removed or not properly seated. Replace and properly seat the bucket. 
 
Other Features 
• 
Bucket Full Light: Illuminates when the bucket is full and needs to be emptied. 
• 
Auto Shut Off: The unit shuts off when the bucket is full, or when the bucket is removed or 
not properly seated. Unit also shuts off when the set humidity has been reached. (The fan 
will continue to run for additional 3 minutes then stop, unit will resume when ambient 
humidity rises 5% above set humidity.) 
• 
Auto Defrost: When frost builds up on the evaporator coils, the compressor will cycle off 
and the fan will continue to run until the frost disappears. 
• 
3 Minute Delay: After the unit has stopped (or powered off), there will be a 3-minute delay 
before it will resume operation again. This is to protect the compressor. Operation will 
automatically start after 3 minutes. 
• 
Check Filter Feature: The system begins calculating the time once fan motor begins 
operation. The check filter feature will be activated when operation time achieves 250 hours 
or more - the clean filter indicator light will begin to flash. After filter has been cleaned and 
replaced, press the Filter button to reset and the clean filter indicator will go off. 
• 
Auto-Restart: If the unit breaks off unexpectedly due to power cut, unit will resume at 
previous setting when power returns. 
• 
Timer On and Timer Off: Unit can be set to auto-start/stop, up to 24 hours: 
When unit is on: press of the Timer button and the Timer-Off indicator will illuminate 
(indicating auto-stop is initiated). Press Timer button again and the Timer-On indicator 
will illuminate (indicating auto-start is initiated).