Maytag MGDX6STBW Installationsanweisungen

Seite von 48
11
A
B
D
C
Plan pipe fitting connection
2.
A combination of pipe fittings must be used to connect dryer 
to existing gas line. A recommended connection is shown. 
Your connection may be different, according to supply line 
type, size, and location.
A. 3/8" flexible gas connector
B. 3/8" dryer pipe 
C. 3/8" to 3/8" pipe elbow
D. 3/8" pipe-to-flare adapter fitting
Open shut-off valve in supply line; valve is open when handle 
is parallel to gas pipe. Then, test all connections by brushing 
on an approved noncorrosive leak-detection solution. 
Bubbles will show a leak. Correct any leaks found.
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
A
B
Connect gas supply to dryer
1.
Remove red cap from gas pipe. Using a wrench to tighten, 
connect gas supply to dryer. Use pipe-joint compound  
on threads of all non-flared male fittings. If flexible metal  
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to action of LP gas. Do not use  
TEFLON
®†
 tape.
Make Gas Connection
Closed valve
Open valve
Open shut-off valve
3.
Non-flared  
male fitting
Flared  
male fitting
Venting
Venting Requirements
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent 
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: 
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
 
Only a 4" (102 mm) heavy metal exhaust vent and clamps may 
be used. 
 
Do not use plastic or metal foil vent.
Rigid metal vent:
 
Recommended for best drying performance and to avoid 
crushing and kinking.
Flexible metal vent: 
(Acceptable only if accessible to 
clean)
 
Must be fully extended and supported in final dryer location.
 
Remove excess to avoid sagging and kinking that may result 
in reduced airflow and poor performance.
 
Do not install in enclosed walls, ceilings, or floors.
 
The total length should not exceed 7
3
/
4
 ft. (2.4 m).
NOTE: 
If using an existing vent system, clean lint from entire 
length of the system and make sure exhaust hood is not plugged 
with lint. Replace plastic or metal foil vents with rigid metal 
or flexible metal vents. Review “Vent System Chart” and, if 
necessary, modify existing vent system to achieve best drying 
performance.