Whirlpool WFG320M0BB Dimensionale Illustrationen

Seite von 2
30" (76.2 cm) Freestanding Gas Range
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
WFG320M0B
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10620413B
1/16/14
A. 36" (91.4 cm)
B. 29 " (75.9 cm)
C. 24¼" (61.6 cm)
D. 46¼" (117.5 cm)
D
C
B
A
⁷⁄₈
Type of Gas
Natural gas:
This range is design-certified by CSA International for use with Natural gas
or, after proper conversion, for use with LP gas.
● 
This range is factory set for use with Natural gas. See “Gas Conversions”
section. The model/serial rating plate located on the oven frame behind
the left side of the broiler door has information on the types of gas that
can be used. If the types of gas listed do not include the type of gas
available, check with the local gas supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas specified
on the model/serial rating plate for use with a different gas without
consulting the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
● 
Provide a gas supply line of 
³⁄₄" (1.9 cm) rigid pipe to the range location.
A smaller size pipe on longer runs may result in insufficient gas supply.
With LP gas, piping or tubing size can be 
¹⁄₂" (1.3 cm) minimum. Usually,
LP gas suppliers determine the size and materials used in the system.
NOTE: 
Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
● 
If local codes permit, a new CSA design-certified, 4-5 ft (122-
152.4 cm) long, 
¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
● 
¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female
pipe threads of the inlet to the appliance pressure regulator.
● 
Do not kink or damage the flexible metal tubing when moving the
range.
● 
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This valve
should be located in the same room but external to the range opening,
such as an adjacent cabinet. It should be in a location that allows ease of
opening and closing. Do not block access to shutoff valve. The valve is
for turning on or shutting off gas to the range.
Electrical:
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-
delay fuse or circuit breaker is also recommended. It is recommended that a
separate circuit serving only this range be provided.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
A. Gas supply line
B. Shutoff valve “open” position
C. To range
A
B
C
Page 1 of 2