1  
PREPARING FOR INSTALLATION
OF NEW DRYER
TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.
DISCONNECTING GAS
NEVER REUSE OLD FLEXIBLE
CONNECTORS.
 
 
connectors when installing gas appliances.
REMOVING LINT FROM WALL EXHAUST 
OPENING
D Remove and discard existing plastic or metal foil transition 
duct and replace with UL listed transition duct.
TURN GAS
SHUT-OFF
VALVE TO THE
OFF POSITION.
DISCONNECT AND DISCARD OLD 
FLEXIBLE GAS CONNECTOR AND 
OLD DUCTING MATERIAL.  
REPLACE WITH NEW CSA(AGA) 
APPROVED FLEXIBLE GAS LINE 
CONNECTOR AND UL APPROVED 
TRANSITION DUCT.
ADJUSTING FOR ELEVATION
‡*DVFORWKHVGU\HUVLQSXWUDWLQJVDUHEDVHGRQVHDOHYHO
operation and need not be adjusted for operation at or below 
2000 ft. elevation. For operation at elevations above 2000 ft., 
input ratings should be reduced at a rate of 4 percent for each 
1000 ft.  above sea level.
‡,QVWDOODWLRQPXVWFRQIRUPWRORFDOFRGHVDQGRUGLQDQFHVRU
in their absence, the NATIONAL FUEL GAS CODE, ANSI Z223.
2
GAS REQUIREMENTS 
F This gas dryer is equipped with a Valve & Burner Assembly for use 
only with natural gas. Using a conversion kit WE25M87 your local 
service organization can convert this dryer for use with propane
(LP) gas. 
ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND
QUALIFIED PERSONNEL AND IN ACCORDANCE  WITH LOCAL CODES AND
ORDINANCE REQUIREMENTS. 
F The dryer must be disconnected from the gas supply piping system  
during any pressure testing of that system at a test pressure in  
excess of 0.5 PSI (3.4 KPa).
F  The dryer must be isolated from the gas supply piping system by
closing the equipment shut-off valve during any pressure testing
of the gas supply piping of test pressure equal to or less than
0.5 PSI (3.4 KPa). 
DRYER GAS SUPPLY CONNECTION
GAS SUPPLY
F A 1/8 in. National Pipe Taper thread plugged tapping, accessible 
for test gauge connection, must be installed immediately 
upstream of the gas supply connection to the dryer. Contact  
your local gas utility should you have questions on the installation  
of the plugged tapping.
F Supply line is to be 1/2 in. rigid pipe and equipped with an acce-
sible shut-off within 6 ft.of, and in the same room with the dryer.
F Use pipe thread sealer compound appropriate for natural or
F
F
F
(listed connector ANSI Z21.24 / CSA 6.10). The length of the
connect shall not exceed 3 ft.
NOTE: Add to vertical dimension the
distance between cabinet bottom to floor
ply.
1 25/32
3 11/32
 3/8 NPT MALE 
 THREAD GAS
 SUPPLY
The installation must conform with local codes, or in the absence 
of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 
54, or the Natural Gas and Propane Installation Code, CSA B149.1.
   
FUse a new CSA Interna-
    
 
   tional  approved flexible 
    
 
   gas supply line. 
    Never reuse old flexible connectors.
FInstall a shut-off valve.
FSecurely tighten all gas connections.
FIf connected to LP gas, have a qualified person make sure gas 
pressure does not exceed 13” water column.
FExamples of a qualified person include: licensed heating personnel, 
authorized gas company personnel, and authorized service personnel.    
FFailure to do so can result in death, explosion, or fire.      
Fire Hazard
Explosion Hazard
 
F
WARNING
WARNING
WARNING