Specifications  
subject to change.
Under-Cabinet Hood Specifications
• 
Product Shipping Weight (Approx.) – 27 Lbs.
• 
Under-Cabinet Installation – can be ducted vertically or horizontally.
• 
Ventilation system can exhaust air outside, either vertically 
through roof or horizontally through wall. (Refer to Ducting Option 
Specifications for outside ventilation.). If ducting outside is not 
possible, the system can be alternately set to recirculate air inside, 
requiring use of recirculating kit, included with hood.
• 
Sones Rating – 7.7 
• 
Voltage Rating – 120V / 60 Hz / 15 Amps
• 
Connected Load (kW Rating) @ 120 Volts = .23 kW  
(For use on adequately wired 120V, dedicated circuit having 2-wire 
service with a separate ground wire. Appliance must be grounded for 
safe operation.)
• 
Amps @ 120 Volts = 1.8 Amps
• 
Always consult local and national electric codes. Check local building 
codes for installation requirements, as they may vary per locale.
• 
Makeup air systems may be required by local building codes 
when using ventilation systems greater than specified CFM of air 
movement. Specified CFM varies per locale.
• 
Connect vent hood with copper wire only. (For installation pre-wired 
with aluminum wiring, refer to Product Installation Guide on web for 
correct wiring procedure.)
• 
Locate vent hood away from strong draft areas, such as windows, 
doors or strong heating vents.
• 
Minimum 24" - 30" installation height allowed from bottom of hood 
canopy to cooking surface; minimum 66" height suggested from  
top of hood to floor.
• 
When installing vent hood under cabinets with recessed bottoms, two 
2"-wide filler strips required with length and thickness determined by 
recess dimensions.
Ducting Option Specifications
• 
Vent system MUST terminate outside through roof or wall; do NOT 
terminate into attic or other enclosed area.
• 
Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum 
vent length or 7" round with 50' maximum vent length. Refer 
to Product Installation Guide on web for calculations needed to 
determine total duct length.
• 
Installation of 7" Round Duct requires use of 7" Round Transition Duct 
(included) and can only be vented vertically. 
• 
To provide efficient performance, length of vent system and number  
of elbows should be kept to minimum. Flexible vent greatly reduces 
performance and is NOT recommended.
• 
Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent 
recommended; plastic or metal foil vent NOT recommended.
• 
For cold weather installation, additional backdraft damper and thermal 
break should be installed. Thermal break will minimize conduction of 
outside temperatures as part of the vent system with damper on cold 
air side of break, as close as possible to where vent system enters 
heated portion of house.
• 
Refer to Product Installation Guide on web for detailed vent system 
preparation instructions.
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• 
Charcoal Filter – (PN # 5304486303).
• 
Duct-Free Kit (Single-Pack) – (PN # 5304455850).
• 
Duct-Free Kit (8-Pack) – (PN # DFKIT368PK).
• 
Damper Kit (6-Pack) – (PN # DAMPKIT6PK).
• 
7"-Round Damper Kit (Single-Pack) – (PN # 5304455851).
36" Under-Cabinet Vent Hood (recirculating model)