TROUBLESHOOTING
If you experience
Possible Causes
Solution
Dryer Operation
Dryer will not run
Door not closed completely.
Make sure the dryer door is closed completely.
PUSH to START knob not pressed 
firmly or held long enough.
Press and hold the PUSH to START knob until you hear the dryer 
drum moving.
Household fuse is blown or circuit 
breaker has tripped.
There may be 2 household fuses or circuit breakers for the dryer. 
Check that both fuses are intact and tight, or that both circuit 
breakers have not tripped. Replace the fuses or reset the circuit 
breaker. If the problem continues, call an electrician.
Incorrect power supply.
Electric dryers require 240-volt power supply. Check with  
a qualified electrician.
Wrong type of fuse.
Use a time-delay fuse.
Dryer will not heat
Household fuse is blown or circuit 
breaker has tripped.
The drum may be turning, but you may not have heat. Electric dryers 
use 2 household fuses or circuit breakers. Replace the fuses or 
reset the circuit breaker. If the problem continues, call an electrician.
Incorrect power supply.
Electric dryers require 240-volt power supply. Check with a qualified 
electrician.
Supply line valve not open.
For gas dryers, make sure that the valve on the gas supply line is 
open.
Unusual Noise
Humming or whining noise 
with Steam cycle selected 
(on some models)
Water inlet valve on dryer is running.
The water inlet valve on the dryer is used during the Steam function. 
If the dryer has just been installed or unused for an extended period, 
the valve may be louder and run longer. This is normal. 
NOTE: The valve may make this noise even with no water line 
connected.
Thumping noise
Dryer hasn’t been used in a while.
This is normal. The thumping sound should diminish after a few 
minutes of use.
Rattling or vibrating noise
A small object caught between the 
edges of dryer drum.
Check the front and rear edges of the drum for small objects. Clean 
out pockets before laundering.
Dryer isn’t properly leveled.
The dryer may vibrate if not properly installed. See the Installation 
Instructions. All four dryer feet should be in firm contact with the 
floor.
Clothing is balled up in dryer.
When balled up, the load will bounce, causing the dryer to vibrate. 
Separate the load items and restart the dryer.
Clicking noise
Gas valve operating.
On gas dryers, you may hear the gas valve clicking as it opens and 
closes. This is normal.
Dryer Results
Clothes are not drying 
satisfactorily or drying 
times are too long
Lint screen is clogged with lint.
Clean lint screen before each load.
The exhaust vent or outside exhaust 
hood is clogged with lint, restricting air 
movement.
Run the dryer for 5-10 minutes. Hold your hand under the outside 
exhaust hood to check air movement. If you do not  
feel air movement, clean exhaust system of lint or replace exhaust 
vent with heavy metal or flexible metal vent. Make sure vent is not 
crushed or kinked. See Installation Instructions.
The exhaust vent is not the correct 
length.
Check that the exhaust vent is not too long or has too many turns. 
Long venting will increase drying times. Make sure vent is not 
crushed or kinked. See Installation Instructions.
The exhaust vent diameter is not the 
correct size.
Use 4" (102 mm) diameter vent material.
The Air Only cycle or Air Fluff 
temperature setting has been selected.
Select the right cycle or temperature for the types of items being 
dried. See “Cycle Guide”.
The load is too large and heavy to dry 
quickly.
Separate the load to tumble freely.
First try the solutions suggested here or visit our website at www.maytag.com/product_help - 