To Replace the Filter:
1. To reinstall the filter, the single slot opening on the long edge 
of the filter is to be toward the front of the range hood. Place 
the back edge of the filter into the channel at the rear of the 
range hood. 
2. Pull the filter retainer toward the front of the range hood and 
push the front of the filter up into place. 
3. Release the filter retainer. It will spring back into place to 
secure the filter.
4. Replace the screw into the filter retainer.
Replacing the Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To 
avoid damage or decreasing the life of the new lamp, do not 
touch lamp with bare fingers. Replace lamp, using tissue or 
wearing cotton gloves to handle lamp.
If new lamps do not operate, make sure the lamps are inserted 
correctly before calling service.
1. Disconnect power.
2. Push up on the lens and turn it counterclockwise.
3. Remove the lamp and replace it with a 120-volt, 50-watt 
maximum halogen lamp with a GU10 base. Turn it clockwise 
to lock it into place.
4. Repeat steps 2-3 for the other lamps if needed.