NOTE
NOTE
Step 1: Verify door alignment
Verify that the door is aligned correctly with the cabinet prior 
to fabricating the custom panel. Failure to do so may result in 
mis-alignment of the custom panel with the hinge bracket. The 
door should be parallel to the sides and top of the refrigerator. 
If alignment is necessary the door may be adjusted by loosen-
ing the 2 screws which secure the top and/or bottom hinge 
adapter brackets, located  on the top and bottom of the door 
and adjusting the door side to side. Use a 5/32” allen wrench, for 
this procedure. (See Figure 9 below). When finished aligning the 
door, tighten the screws securely.
Hinge adapter bracket lo-
cated on the top and bottom 
of the door. 
Remove top 
hinge pin to re-
move the door.
9/32”
(7mm)
Figure 9
Door should be 
parallel to top 
and sides of ice 
machine.
Step 2: Remove door
Remove the top hinge pin from the hinge with an 1/8” allen 
wrench. Remove the door by angling the top of the door out-
ward and lifting the door off the bottom hinge.
(See detail in Figure 9).
Step 3: Remove gasket
Lay the door on its front being careful not to scratch it. To gain 
access to the screw holes remove the door gasket by peeling up 
and out of the channel.
Step 4: Cut overlay panel
Depending on the ice machine model cut the overlay panel to 
the dimensions shown in Figure 10. 
305/16”
(77.0cm)
145/8”
(37.1cm)
Front of
overlay
panel
Figure 10
For model 25iM
Step 5: Drill hinge clearance holes in overlay panel
Set the overlay panel on the door front, align the edges, and 
clamp together. Clamp the panel firmly but be careful not to 
damage the door or the panel. Mark center of hinge adapter 
hole on wood panel, top and bottom. (See Figure 11.) Remove 
wood panel from door and drill 5/16” (8mm) diameter clearance 
holes into the overlay panels 3/4” (20mm) deep. These will be 
clearance holes for the top and bottom hinge pins. 
This is also a convenient time to locate and drill the holes for 
your handle. Most often the handle is to match that of the sur-
rounding cabinetry. If your handle attaches from the back-side 
of the custom panel, locate the mounting holes while the panel 
is attached to the door and cabinet. After the panel is removed 
from the door, drill the mounting holes from the front, to the 
recommended diameter of the handle manufacturer. Counter 
bore the back-side of the panel so the screw heads do not inter-
fere with the surface of the door.
For overlay with lock option panel thickness to be  3/4” (19mm) 
maximum to 5/8” (16mm) minimum.
Weight of the overlay panel should not exceed 20 pounds (9.1 
kilograms).
For the door to close properly, it is necessary to maintain a mini-
mum space of 9/32” (7mm) between the door and cabinet flange 
(See Figure 9). This space can be adjusted by adjusting the top 
and bottom hinge adapter brackets.
FULL OVERLAY PANEL INSTALLATION INSTRUCTIONS
12