Document Number: 424077 Revision: 2.0Thermal/Mechanical 
Specifications and Design Guidelines
Temperature readings from the processor are always negative in a 2’s complement 
format, and imply an offset from the reference TCC activation temperature. As an 
example, assume that the TCC activation temperature reference is 100 °C. A PECI 
thermal reading of -10 indicates that the processor is running at approximately 10 °C 
below the TCC activation temperature, or 90 °C. PECI temperature readings are not 
reliable at temperatures above TCC activation (since the processor is operating out of 
specification at this temperature). Therefore, the readings are never positive. 
Note that changes in PECI data counts are approximately linear in relation to changes 
in temperature in degrees centigrade. A change of ‘1’ in the PECI count represents 
roughly a temperature change of 1 degree centigrade. This linearity is approximate and 
cannot be ensured over the entire range of PECI temperatures, especially as the delta 
from the maximum PECI temperature (zero) increases. 
6.3.3.3
Processor Thermal Data Sample Rate and Filtering
The processor digital thermal sensor (DTS) provides an improved capability to monitor 
device hot spots, which inherently leads to more varying temperature readings over 
short time intervals. To reduce the sample rate requirements on PECI and improve 
thermal data stability versus time the processor DTS implements an averaging 
algorithm that filters the incoming data before reporting it over PECI.
6.3.3.4
Reserved Values
Several values well out of the operational range are reserved to signal temperature 
sensor errors. These are summarized in 
.
§
Table 6-7.
Error Codes and Descriptions
Error Code
Description
8000h
General Sensor Error (GSE)
8002h
Sensor is operational, but has detected a temperature below its operational range 
(underflow)