SPECIFICATIONS
EXHAUST FANS
AKF80LS
80 CFM/0.8 SONES @ 0.10" WG.
HVI CERTIFIED 120 Volts, 0.75 amps, 60 hz.
• Grill
White, polymeric grill secured in place with torsion springs;
easily removed if necessary, dimensions - 11" x 13
3/4
". Moonstone
glass lens.
• Blower Wheel
Balanced polymeric dual inlet blower wheel 5
1/4
"  dia. x 2
27/32
"
depth, 30 paddles, secured in place via press fit.
• Motor
Enclosed 4 pole electronically balanced permanently split
capacitor motor (PSC); life time lubricated, suitable for
continuous operation. Motor bearings - ball. Rated 115/120 volts,
60 Hz, 0.30 amps.
• Fan Housing
23 gauge galvanized steel housing.
Overall dimensions 10
7/8
" x 9
3/8
" x 7
7/8
".
• Duct Collar
4" round, zinc plated metal collar adapter. 4" spring loaded
aluminum backdraft damper.
• Ventilating Area
For bathrooms up to 80 sq. ft. For other rooms up to 100 sq. ft.
• Electrical Connections
1/2
" electrical knockouts provided. Easy wiring access via either
internal or external wiring compartment cover.
CUL/HVI
Canada: 110 Glidden Road
Brampton, Ontario L6T 2J3
Tel: (905) 456-2033
Fax: (905) 456-1015
U.S.: 820 Lincoln Drive
West Chester, Pennsylvania  19380-4466
Tel: (610) 692-7400 • 877-304-3785
Fax: (610) 696-8048
Updated 7-06
Specifications subject to change without notice.
• Lighting
Electronic Quick Start Ballast – rated 26 Watt – Use Triple 4 pin
PL lamp. Maximum 26 Watt.
• Unit Mounting
The housing will mount in ceilings with  at least 8" of clearance
and through drywall thickness up to 
3/4
", with a rough-in opening
of 11
1/8
" x 9
5/8
". Rated for ceilings insulated to R-40. The housing
will mount either between 16" or 24" on center joists, using the
4 supplied housing mounting rails. The housing mounting rails
can be adapted for overhead mounting (hardware not provided).
• Single Pack Shipping Info
Box Dim Box Dim: 14
1/8
" x 11
5/8
" x 12"
UPC: 0-8316228051-0
Shipping Weight: 11.5 lbs.
C
US
PROJECT
LOCATION
CONTRACTOR
ARCHITECT
ENGINEER
SUBMITTED BY
DATE
FAN
MODEL
CFM
IN
RPM
WATTS
AMPS
SONES
QTY
OPTIONAL EQUIPMENT
NUMBER NUMBER
W.G.
& REMARKS
Acceptable for use over tub or shower when
installed in a GFCI protected branch circuit.
PERFORMANCE
HVI Sones
Fan Speed
Power
Static Pressure (inches of w.g.)
@ .1 SP
RPM
Watts
0
0.05
0.1
0.125
0.15
0.2
0.25
0.3
Air Flow - CFM
87
84
80
77
73
64
52
40
0.8
984
26
7
7/8
"
4"
10
7/8
"
9
3/8
"
11"
13
3/4
"