Southbend SB1059F Benutzerhandbuch

Seite von 140
For Machines Mfg. Since 3/11
EVS Toolroom Lathe w/DRO
-31-
P R E P A R A T I O N
Electrocution could occur if you attempt this 
procedure with the power wires connected to 
the power source. The incoming power wires 
must be disconnected from power before 
performing this procedure.
L3
L2
L1
To Power 
Supply
Hot
MASTER 
POWER SWITCH
Hot
Hot
Ground
Figure 22. Power connection at master power switch.
4.
  Make sure the wires have enough slack so 
that they do not bind at the terminals.
5.
  Close and lock the main electrical box door.
 
3.
  Connect the incoming hot wires to the 
upper master power switch terminals and 
the ground wire to the ground terminal, as 
illustrated in Figure 22.
Connecting Power
1.
  Make sure the master power switch is 
turned to the OFF position, then open the 
electrical cabinet door.
2.
 Refer 
to 
Figure 21 to identify the master 
power switch and the hole at the bottom left 
of the electrical cabinet for the incoming 
power.
Figure 21. Electrical cabinet.
Incoming Power
Master
Power
Switch
To avoid unexpected start-up of lathe 
components, keep the master power switch 
turned OFF until instructed otherwise in the 