Printer Adjustments
48
Adjusting the Reflective sensor
1. The reflective sensor is selected.
2. With the reflective sensor selected, install the label media so
that it is between the platen roller and the media sensor.
Be careful that black mark and media gap do not pass the
media sensor
. Then close the sensor arm and the printhead.
3. If the Pause Key is pressed then released while the MENU key is
continually pressed, the sensor is automatically adjusted.
Sensor  Cal  Mode
Executing
4. When automatic adjustment stops normally, “Succeeded” is
displayed by the LCD. If it stops abnormally (adjustment is
impossible), ERROR LED flashes and “Failed” is displayed on
the LCD.
Sensor  Cal  Mode
Succeeded
5. If the Cancel (STOP) key is pressed, the Printer completes sensor
adjustment and the printer restarts.
Sensor Adjustments and Calibration
Black mark
Label
Liner media
Bottom sensor