Citizen Systems CL-S700 Benutzerhandbuch

Seite von 70
61
Appendixes
Interfaces
This printer is connected to a computer and prints according to commands
sent from the computer.
There are three types of computer interfaces, and these are connected to
devices suited to each type of interface. The printer can also be connected
to a computer by the optional Ethernet.
System
Start/stop asynchronous duplex communication
Signal level
RS-232C
Baud rate
2400, 4800, 9600, 19200, 38400,57600, 115200bps
Bit length
7Bit, 8Bit
Stop bit
1Bit, 2Bit
Parity
Odd, even, none
Connector
D-SUB 25PIN
Serial Interface
Specifications
Pin No. Signal code
Signal name
Function
1
FG
Protective
Protective grounding
grounding
2
TXD
Transmitted data
Signal line that transmits data from the
printer to other devices
3RXD
Received data
Signal line that transmits data from other
devices to the printer
4
RTS
Transmission
Pull up to +5.4V through 3.3k
Ω
request
5
NC
------
Not used
6
DSR
Data set relay
Signal line that is active when an external
device can interface with the printer
7
SGND
Signal line
Shows the ground level of the signal line
ground
8-13NC
------
Not used
14
VCC
+5V
(FACTORY USE ONLY )
15-19
NC
------
Not used
20
DTR
Data terminal
Signal line that is active when an external
relay
device can interface with the printer
21-25
NC
------
Not used
Signal line and pin arrangement