Nortel Networks 400 4.0 Benutzerhandbuch

Seite von 382
Chapter 2 Introducing the BCM hardware
65
BCM200/400 4.0 Installation and Maintenance Guide
Figure 39   BCM400 redundant power supply and modules
Figure 40   BCM400 redundant power supply connectors
In addition, international (non-North American) users require a power supply adapter cord for 
each main unit and expansion unit.
Power supply module 
removed from the redundant 
power supply unit
Power supply module 
inserted in the 
redundant power 
supply unit
Connector Configuration for 
Redundant Sparkle Power Supply
Cable Lengths and 
Markings
550mm (P2)
550mm (P3)
325mm to first 
(P4), +50mm to 
next (P5), 
+100mm to last 
(P6) (total 475mm)
340mm to first 
(P7)(right angle) , 
+150mm to next 
(P8) (total 490mm)
515mm (P1)
515mm (P9)
515mm (PA)
300mm (PB)
Route to Media bay backplane 1: Tie any slack at 
the connector (behind the MBM).
Route to Media bay backplane 2: Tie any slack at 
the connector (behind the MBM).
To hard disk: Tie any slack at the power supply. 
Tuck any loose connectors under the hard disk 
Unused. Tie to the center of the hard disk cage.
Route to the I/O card.
Route to the I/O card.
Route to the I/O card.
Unused
Purpose and Notes