Meridian Data 16i Benutzerhandbuch
Chapter 2 Hardware Installation
2-9
corresponding connector on the backplane board. If the
front flap is not closed properly, the connection between
the hard drive and the subsystem may come loose and
mysterious drive signals may result.
Step 5.
Lock the flap into place by turning the key-lock until the
groove on its face is pointing down (vertical orientation).
(See Figure 2-8)
Figure 2-8: Drive Tray Key-lock Rotation
Step 6.
Once the drive bays are populated and the subsystem
powered on, the RAID controller will automatically spin
up the hard drives and recognize their presence.
2.8 Rack/Cabinet Installation
The subsystem is designed to fit into a variety of 19-inch rack cabinets or
racks. Make sure you have an appropriate site location and cables prepared
with adequate lengths to connect to mains and other devices.
The subsystem should be installed in the rack or cabinet before the hard
drives and the drive trays are installed. If the drive trays with the associated
hard drives are installed, the subsystem will be too heavy to mount into a
rack or cabinet. When installing the subsystem into a rack or cabinet it is
advisable that two (2) people assist in the mounting process.
For details on the use of the rackmount rails, please refer to the installation
instructions that came with them.