Remove all packaging from the unit, hose
and other accessories; ensure that you
have removed all of the accessories before
discarding the packaging.
Ensure that the dust canister and filters
are correctly fitted.
Locate the crush proof hose and push the
connection point into the hose inlet
connection on the front of the unit, until a
“click” sound is heard.
Connect the wide end of the metal wand
to the hose end, and push together firmly.
Fit the floor tool to the narrow end of
the wand/s and push together firmly.
Fully extend the power cord by pulling
the power plug (situated at the rear of the
unit) out from the unit, until the yellow
tape on the cord is shown.
ENSURE THAT YOU DO NOT
OVER EXTEND THE POWER CORD
– DO NOT EXTEND PAST THE RED
WARNING TAPE  ON THE  CORD
Plug into a 230/240v power point and
switch the power on.
To commence vacuuming push down on
the on/off foot pedal, at the top, rear of
the unit.
When vacuuming is complete, push down
on the ‘on/off’ pedal to switch off.
Turn the power off at the outlet and then
remove the power cord from the power
outlet (when removing plug from the
power outlet grasp the plug not the cord).
To retract the cord push down on the
‘cord rewind’ pedal.
IMPORTANT: HOLD THE PLUG END
WHEN  RETRACTING THE  CORD TO
PREVENT IT FROM STRIKING YOU OR
THE VACUUM.
ALWAYS  ENSURE THAT THE
DUST CANISTER AND THE
MOTOR PROTECTION FILTER ARE
CORRECTLY FITTED. NEVER
OPERATE WITHOUT THE  DUST
CANISTER AND FILTERS IN PLACE.
V
Va
arriia
ab
blle
e  P
Po
ow
we
err  C
Co
on
nttrro
oll
The On/off button, on the top of the unit,
is also to be used for variable power
control. Turn the control clockwise for
maximum power for vacuuming hard floor
and carpet surfaces.Turn the control anti-
clockwise for minimum power when using
the crevice and brush tools.
C
Crre
ev
viic
ce
e  a
an
nd
d  b
brru
ussh
h  tto
oo
oll  a
ac
cc
ce
esssso
orriie
ess
The crevice tool is ideal for vacuuming
hard to reach places such as the edges
along skirting boards.
The brush tools can be used to vacuum
delicate surfaces and areas such as shelves
and venetian blinds.
Set the variable speed control between
minimum and medium power when using
the tool accessories.
Turn off the vacuum cleaner when
changing any attachments.
D
Du
usstt  c
ca
an
niisstte
err  iin
nd
diic
ca
atto
orr  a
an
nd
d
d
diissp
pe
en
nssiin
ng
g  tth
he
e  d
du
usstt  c
ca
an
niisstte
err
The dust canister should be emptied
when full.The dust canister indicator
window will gradually turn red as the
5
canister fills up.When the dust canister
indicator displays ‘red’ it is time to empty
the canister. Otherwise you can look 
at the canister at the back end of the unit
and decide when you would like to empty
it.
Always switch appliance off, then switch
off at the power outlet and unplug the
appliance prior to replacing filters or
emptying the dust canister.
To remove the dust canister, ensure the
unit is down on its wheels; Remove the
dust canister by clasping the handle and
pressing down on the button above the
dust canister. Once released slowly pull
the canister toward you.
To empty the dust canister simply place it
above the rubbish bin; lift the “lift and
press” lever and then press the button.
The bottom of the canister will release
and the dust and compiled dirt will be
dispensed.
IMPORTANT: DO NOT USE THE
UNIT WITHOUT A DUST CANISTER 
IN PLACE
C
Clle
ea
an
niin
ng
g  a
an
nd
d  rre
ep
plla
ac
ciin
ng
g  ffiilltte
errss
Filters must be cleaned from time to time
to remove the fine dust particles that have
been collected.
1. Remove the dust canister from the unit
2. Lift the lid of the dust canister
3.Take off the mesh filter by lifting it
vertically; this filter can be washed in
luke warm water. Ensure you let the
filter completely dry naturally before
next use.
4.To remove the HEPA filter rotate the
filter in an anti-clockwise position until
released.Then lift the HEPA filter
vertically to remove.
5.Tap and shake the filter until all the fine
dust particles are removed. However
after approximately 6 months the filter
should be replaced.
6.To place the filter back in the dust
canister simply place the HEPA filter in
the dust canister lid and turn the filter
in a clockwise direction to lock it 
in place.
7.To place the mesh filter bracket back in
place, ensure that it is completely dry
before use. Simply place the filter on
top of the HEPA filter and ensure the
indents in the mesh filter holder meet
with the grooves in the dust canister
lid.This will ensure that the mesh filter
bracket is locked in place.
8. Place the complete filter assembly back
on top of the dust canister. Place the
dust canister back in the vacuum
cleaner for next use.
M
Mo
otto
orr  p
prro
otte
ec
cttiio
on
n  ffiilltte
err
The motor protection filter must always
be in place when operating the vacuum
otherwise damage to the motor may occur.
To replace the motor protection filter –
remove the dust canister.The motor
protection filter is located at the rear of
the inner chamber. Pull the plastic filter
holder toward you to remove. Replace
the filter and push the holder back in
place once filter replacement been made.