Figure 3 - Assembling Hood
Hood
Sheet Metal 
Screws
Firebox 
Top
Louver
AIR FOR COMBUSTION 
AND VENTILATION
  WARNING:  This  fireplace 
shall not be installed in a con-
fined  space  or  unusually  tight 
construction unless provisions 
are provided for adequate com-
bustion and ventilation air. Read 
the following instructions to in-
sure proper fresh air for this and 
other fuel-burning appliances in 
your home.
Todayʼs homes are built more energy efficient 
than ever. New materials, increased insulation, and 
new construction methods help reduce heat loss 
in homes. Home owners weather strip and caulk 
around windows and doors to keep the cold air out 
and the warm air in. During heating months, home 
owners want their homes as airtight as possible.
While it is good to make your home energy effi-
cient, your home needs to breathe. Fresh air must 
enter your home. All fuel-burning appliances need 
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel 
burning appliances draw air from the house to 
operate. You must provide adequate fresh air for 
these appliances. This will insure proper venting 
of vented fuel-burning appliances.
PROVIDING ADEQUATE 
VENTILATION
The following are excerpts from National Fuel 
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, 
Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol-
lowing ventilation classifications:
1.  Unusually Tight Construction
2.  Unconfined Space
3.  Confined Space
The information on pages 6 through 8 will help 
you  classify  your  space  and  provide  adequate 
ventilation.
Unusually Tight Construction
The  air  that  leaks  around  doors  and  windows 
may provide enough fresh air for combustion and 
ventilation. However, in buildings of unusually 
tight construction, you must provide additional 
fresh air.
Unusually tight construction is defined as 
construction where:
a.  walls and ceilings exposed to the out-
side  atmosphere  have  a  continuous 
water  vapor  retarder  with  a  rating  of 
one perm (6 x 10
-11
 kg per pa-sec-m
2
) or 
less with openings gasketed or sealed 
and
b.  weather stripping has been added on 
openable windows and doors and
c.  caulking  or  sealants  are  applied  to 
areas  such  as  joints  around  window 
and door frames, between sole plates 
and floors, between wall-ceiling joints, 
between  wall  panels,  at  penetrations 
for plumbing, electrical, and gas lines, 
and at other openings.
 
If your home meets all of these three 
criteria,  you  must  provide  additional 
fresh  air.  See  Ventilation  Air  From 
Outdoors
, page 8.
If your home does not meet all of the three 
criteria  above,  proceed  to  Determining 
Fresh-Air Flow For Fireplace Location
.
3.  Locate four black phillips sheet metal screws 
in hardware packet.
4.  Slide hood between louver and firebox top and 
align screw holes.
5.  Insert screws as shown in Figure 3. Tighten 
screws firmly.
HOOD ASSEMBLY