33.2.8
Standby Control Register 8 (STBCR8)
STBCR8 is an 8-bit readable/writable register that controls the operation of each module.
Note: When writing to this register, see section 33.4, Usage Notes.
7
6
5
4
3
2
1
0
Bit:
Initial value:
R/W:
1
1
1
1
1
1
1
R/W
R
R
R
R
R
R/W
1
R
-
MSTP
87
-
-
-
MSTP
80
-
-
Bit Bit
Name
Initial
Value R/W Description
Value R/W Description
7
MSTP87
1
R/W
Module Stop 87
When the MSTP87 bit is set to 1, the clock supply to
the motor control PWM timer is halted.
the motor control PWM timer is halted.
0: The motor control PWM timer runs.
1: Clock supply to the motor control PWM timer is
halted.
6 to 1
All 1
R
Reserved
These bits are always read as 1. The write value
should always be 1.
should always be 1.
0
MSTP80
1
R/W
Module Stop 80
When the MSTP80 bit is set to 1, the clock supply to
the decompression unit is halted.
the decompression unit is halted.
0: The decompression unit runs.
1: Clock supply to the decompression unit is halted.