Deploying FCoE (FIP Snooping) on Dell 
PowerConnect
 10G Switches: M8024-k, 8024, and 8024F 
53 
 
vlan 1000 
  fcoe vsan 2  
  name FCoE_VLAN 
vsan database 
  vsan 2  
 
 
interface port-channel2 
  switchport mode trunk 
  switchport trunk native vlan 20 
  switchport trunk allowed vlan 1000 
 
interface vfc3 
  bind mac-address 14:fe:b5:8e:5b:f2 
  no shutdown 
 
interface vfc4 
  bind mac-address 14:fe:b5:8e:5b:f0 
  no shutdown 
 
interface vfc5 
  bind mac-address 14:fe:b5:8e:5c:09 
  no shutdown 
 
interface vfc6 
  bind mac-address 14:fe:b5:8e:5c:0b 
  no shutdown 
 
interface vfc7 
  bind mac-address 14:fe:b5:8e:5c:26 
  no shutdown 
 
interface vfc8 
  bind mac-address 14:fe:b5:8e:5c:24 
  no shutdown 
vsan database 
  vsan 2 interface vfc3 
  vsan 2 interface vfc4 
  vsan 2 interface vfc5 
  vsan 2 interface vfc6 
  vsan 2 interface vfc7 
  vsan 2 interface vfc8 
  vsan 2 interface fc1/31 
  vsan 2 interface fc1/32 
 
feature npv 
feature npiv 
 
 
interface fc1/31 
  switchport trunk mode on 
  no shutdown