Desa VSGF36NTA Benutzerhandbuch

Seite von 40
www.desatech.com
116746-01A
25
CLEANING AND 
MAINTENANCE
 WARNING: Turn off fireplace 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burner  and  cir-
culating  air  passageways  of 
fireplace  clean.  Inspect  these 
areas  of  fireplace  before  each 
use.  Have  fireplace  inspected 
yearly  by  a  qualified  service 
person.  Fireplace  may  need 
more frequent cleaning due to 
excessive  lint  from  carpeting, 
bedding material, pet hair, etc.
  WARNING:  Failure  to  keep 
the  primary  air  opening(s)  of 
the burner(s) clean may result in 
sooting and property damage.
BURNER INJECTOR HOLDER AND 
PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount 
of air to mix with the gas. This provides a clean 
burning flame. Keep these holes clear of dust, dirt, 
lint and pet hair. Clean these air inlet holes prior to 
each heating season. Blocked air holes will create 
soot. We recommend that you clean the unit every 
three months during operation and have heater 
inspected yearly by a qualified service person.
We  also  recommend  that  you  keep  the  burner 
tube and pilot assembly clean and free of dust and 
dirt. To clean these parts we recommend using 
compressed air no greater than 30 PSI. Your local 
computer store, hardware store or home center 
may carry compressed air in a can. You can use a 
vacuum cleaner in the blow position. If using com-
pressed air in a can, please follow the directions on 
the can. If you donʼt follow directions on the can, 
you could damage the pilot assembly.
1.  Shut off the unit, including the pilot. Allow 
the unit to cool for at least thirty minutes.
2.  Inspect  burner,  pilot  and  primary  air  inlet 
holes on injector holder for dust and dirt (see 
Figure 39).
3.  Blow air through the ports/slots and holes in 
the burner.
4.  Check the injector holder located at the end 
of the burner tube again. Remove any large 
particles of dust, dirt, lint or pet hair with a 
soft cloth or vacuum cleaner nozzle.
5.  Blow air into the primary air holes on the 
injector holder.
6.  In case any large clumps of dust have now been 
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the 
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about 
two inches from where the pilot flame comes out 
of the pilot assembly (see Figure 40). With the unit 
off, lightly blow air through the air inlet hole. You 
may blow through a drinking straw if compressed 
air is not available.
Figure 39 - Injector Holder On Outlet 
Burner Tube
Burner 
Tube
Primary Air 
Inlet Holes
Ports/
Slots
Figure 40 - Pilot Inlet Air Hole
Burner 
Tube
Pilot 
Assembly
Pilot Air 
Inlet Hole
Ports/Slots
Injector 
Holder