TO TEST 
Make sure all control valves are in the “OFF” position. 
Turn the gas supply on. Check all connections from the 
L.P. cylinder up to and including the connection to the 
manifold pipe assembly (the pipe that goes to the 
burner). Soap bubbles will appear where a leak is 
present. If a leak is present, immediately turn off gas 
supply, tighten any leaking fittings, turn gas on, and 
recheck. Should the gas continue to leak from any or all 
of the fittings, turn off the gas supply, and contact our 
customer service at 1-800-913-8999. 
 
Only those parts recommended by the manufacturer 
should be used on the grill. Substitution can void the 
warranty. Do not use the grill until all connections have 
been checked and do not leak. 
 
ALWAYS CHECK FOR LEAKS AFTER 
EVERY L.P. TANK CHANGE
 
 
Check all gas supply fittings for leaks before each use. It 
is handy to keep a spray bottle of soapy water near the 
shut-off valve of the gas supply line. Spray all the 
fittings. Bubbles indicate leaks. 
 
Disconnected L.P. cylinders must have threaded valve 
plugs tightly installed, and must not be stored in a 
building, garage or any other enclosed area. 
 
The gas must be turned off at the supply cylinder when 
the unit is not in use. 
 
If the appliance is stored indoors the cylinder must be 
disconnected and removed from the appliance. Cylinders 
must be stored outdoors in a well-ventilated area out of 
the reach of children. 
 
 
Gas flow check:
Each grill burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may 
make it necessary to adjust the burners. The flames of the burners should be visually checked. 
 
Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist, check if the 
air shutter or burner ports are blocked by dirt, debris, spider webs, etc.
 
 
INSTALLER FINAL CHECK   LIST 
 
ˆ  Specified clearance maintained 24” from 
combustibles. 
ˆ  All internal packaging removed. 
ˆ  Knobs turn freely. 
ˆ  Burners are sitting properly on orifices. 
ˆ  Pressure regulator connected and set for 11.2” W.C. 
L.P. gas. Gas connections to grill using hose & 
regulator assembly provided (pre-set for 11.0” water 
column). 
ˆ  Unit tested and free of leaks. 
ˆ  User informed of gas supply shut off valve location. 
 