ACR Electronics ARX-50 Benutzerhandbuch

Seite von 13
Y1-03-0229C 
 
SECTION 5 - MAINTENANCE 
 
The following maintenance schedule is recommended: 
 
Action 
Description 
Frequency 
Visual inspection 
Inspect the antenna, cables and 
connections. Ensure that the cable is 
attached properly and the unit has not been 
damaged. 
Every 6 months 
Performance 
test 
Verify that the system is operating by 
using the training mode with a training 
beacon 
Every year 
Clean exterior 
Using  a  mild,  sudsy  solution  such  as 
dishwashing liquid, wipe the surface of 
the  ARX-50  with  a  damp  cloth  to 
remove film, salt and sand 
As needed 
 
APPENDIX A - SPECIFICATIONS 
 
General 
Carrier frequency 
121.5 MHz or 121.65 MHz, user selectable 
Sensitivity 
<0.2 µV (at antenna output) 
VHF antenna 
Flexible monopole 
Modulation  
Swept tone 
Electrical input power 
+10.5 V to +28 V DC, 120 mA average, 400 mA 
maximum 
Alert methods 
 
Bright red flashing led 
 
L
oud audible alarm (≈70dBA @ 1m) 
 
External speaker connection (8v maximum) 
 
Relay contacts: normally open (2 A/30 V 
maximum) 
Regulation conformity 
Safety 
IEC 60945, EN50371 
EMI/EMC 
IEC 60945 
RoHS/WEEE 
European Directive 2002/95/EC 
Physical 
Dimensions 
5.3” X 3.7” X 1.5” (13.46 X 9.40 X 3.81cm) 
Weather resistance 
IP65 (when included monopole antenna is 
correctly installed) 
Operating temperature 
-4
°F to +131°F(-20°C to +55°C) 
Storage temperature  
-40
°F to +158°F (-40°C TO +70°C) 
Weight 
0.8 lbs (362.87 g)