Installing the HI400
16
Mounting your inverter
The HI400 inverter must be mounted flat (for example, on or 
under a horizontal surface) in order to comply with safety 
agency requirements.
To mount your HI400 inverter:
1. Turn the On/Off switch on the inverter to the off position.
2. Fasten the inverter to the mounting surface, using four 
#10 pan head steel wood screw (5/8” long minimum) or 
#10 bolts inserted through the mounting holes in the 
flanges (running along the sides of the inverter).
Ventilated
See the warning on 
. Allow at least 5 
inches of clearance on each size of the 
inverter for air flow. Do not allow the 
ventilation openings on the unit to become 
obstructed. Make sure the compartment in 
which the inverter is installed allows airflow 
through the compartment.
Safe
See the warning on 
. Do not install 
the inverter in the same compartment as 
batteries or in any compartment capable of 
storing flammable liquids like gasoline. 
Close to battery 
compartment 
and the AC 
source and load
Avoid excessive cable lengths (these reduce 
input and output power due to wire 
resistance). It is preferable to have lengthier 
AC cables than DC cables, as the AC current 
is far lower than the DC. Use the 
recommended cable sizes.
Protected from 
battery acid and 
gases
Never allow battery acid to drip on the 
inverter or its wiring when filling or reading 
its specific gravity. Do not mount the unit 
where it will be exposed to gases produced 
by the batteries. These gases are corrosive 
and prolonged exposure will damage the 
inverter.