Whirlpool WFG114SW Merkblatt

Seite von 1
®
30" Freestanding Gas Range
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
SF114PXS
WFG114SV
WFG114SW
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Gas supply:
Use 
³⁄₄" rigid pipe gas supply line to
the range location. A smaller size pipe on long
runs may result in insufficient gas supply. With
L.P. gas, piping or tubing size can be 
¹⁄₂"
minimum. If local codes permit, it is
recommended that new flexible metal tubing,
design-certified by CSA, 
¹⁄₂" or ³⁄₄" I.D., be used for
connecting the range to the rigid gas supply line. A
¹⁄₂" male pipe thread is needed for connection to
pressure regulator female pipe threads. An
individual manual shutoff valve must be located in
the same room, but external to the range.
Electrical:
A 120-volt, 60 Hz, AC-only, 15 amp,
electrical supply fused on both sides of the line. A
separate circuit is recommended. A time-delay
fuse or circuit breaker is recommended. 
Ref. W10032050B
9/22/10
*** NOTE: 24" (61.0 cm) min. when bottom of wood or metal cabinet is
protected by not less than 
¹⁄₄" (6.4 mm) flame retardant millboard
covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm)
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm)
copper.
30" (76.2 cm) min. clearance between the top of the cooking
platform and the bottom of an unprotected wood or metal cabinet.
Contact a qualified floor covering
installer to check that the floor
covering can withstand at least 200°F.
Use an insulated pad or 
¹⁄₄" (6.4 mm)
plywood under range if installing
range over carpeting.
For minimum clearance
to top of cooktop, see
NOTE.***
Do Not seal the range to
the side cabinets.
If cabinet depth is greater
than 24" (61.0 cm), oven
frame must extend
beyond cabinet fronts by
¹⁄₂" (1. 3 cm) min.
18" (45.7 cm) min.
clearance upper
side cabinet to
countertop
13" (33.0 cm) 
max. upper
cabinet depth
30
¹⁄₈" (76.5 cm)
opening width
30" (76.2 cm) min.
cabinet opening 
width
8"
(20.3 cm)
2"
(5.1 cm)
10"
(25.4 cm)
24"
(61 cm)
5"
(12.7 cm)
5"
(12.7 cm)
3"
(7.6 cm)
2" (5.1 cm) min.
countertop space to
side wall or other
combustible material
This shaded area
recommended
for installation of
gas pipe.
This shaded area
recommended for
electrical outlet.
29
⁷⁄₈" (75.9 cm)
width
46
¹⁄₄" (117.5 cm)
overall height for 
tall backguard 
models
24
¹⁄₄" (61.6 cm)
36"
(91.4 cm)
cooktop
height
26
³⁄₄" (67.9 cm)
depth with handle