ELECTRICAL CONNECTION 
The appliance shall be connected to a single 
phase electric line rated at 120/208Vac or 
120/240Vac and 60Hz frequency. 
 
Electric power rating: 
‐ 120/208Vac: 6700 Watt or 32 A max. 
‐ 120/240Vac: 8500 Watt or 37 A max. 
 
Heating elements (240V)power rating: 
 
LEFT OVEN: 
‐ Oven bake element = 2100 Watt 
‐ Oven circular element = 3300 Watt 
‐ Oven broil element = 3400 Watt 
 
RIGHT OVEN: 
‐ Upper + broil element = 900+1100 Watt 
‐ Bottom element = 900 Watt 
 
WORKTOP ELE. GRIDDLE ELEMENT = 1100 Watt 
 
Install a suitable electric power supply receptacle 
connection type NEMA 14‐50R able to support a 
load of at least 40 A (per line) according to local 
code requirements. For four or three wires power 
supply connection system see diagram below. 
 
 
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R 
 
 
 
 
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R 
 
 
Check your local code for which of the options 
below  should be used  in grounding the 
receptacle power supply connections. 
 
 
 
OPTION 1 – FOUR Wires connection:  
‐ Connect the L1 receptacle terminal to the 
incoming BLACK electrical supply wire (L1‐hot 
wire) 
‐ Connect the L2 receptacle terminal to the 
incoming RED electrical supply wire (L2‐hot 
wire) 
‐ Connect the NEUTRAL receptacle terminal to 
the incoming NEUTRAL (WHITE) electrical 
supply wire 
‐ Connect the GROUND receptacle terminal to 
the incoming GROUND (GREEN) electrical 
supply wire 
 
OPTION 2 - THREE-Wires connection:  
‐ Connect the L1 receptacle terminal to the 
incoming BLACK electrical supply wire (L1‐hot 
wire) 
‐ Connect the L2 receptacle terminal to the 
incoming RED electrical supply wire (L2‐hot 
wire) 
‐ Connect the NEUTRAL with the GROUND 
receptacle terminal to the incoming NEUTRAL 
(WHITE) electrical supply wire 
DO NOT USE EXTENSION CORDS WITH THIS 
APPLIANCE AS IT MAY RESULT IN FIRE, 
ELECTRIC SHOCK OR OTHER type of 
PERSONAL INJURY. 
 
The appliance is equipped at the factory with an 
electric supply cord set 4 wires type with ring 
terminals (L1, L2, N, Ground) suitable for range 
use  UL/CSA  listed  type  SRDT/DRT  2x6AWG  (L1, 
L2)+2x8AWG (N, G) rated 300V, 40 or 50A with 
fused plug type NEMA 14‐50P; cable length 1,5 
m.; in case the supply cord set must be replaced, 
it shall be replaced with an identical set having 
the same technical specs and following carefully 
the  instructions and diagrams below: 
1)   Disconnect appliance from electrical power 
supply receptacle 
2)   Slide out the appliance from installation place 
to access to back enclosure panel 
3)   Remove back enclosure panel by removing 
the 6 screws as shown below