Bertazzoni X)486GPIRVI Benutzerhandbuch

Seite von 52
 
19
 
 
 
 
GAS CONNECTION 
All gas connections must comply with national 
and local codes. The gas supply line (service) 
must be the same size or greater than the inlet 
line of the appliance. This range uses a 1/2" NPT 
inlet (see drawing below for details of gas 
connection). On all pipe joints use appropriate 
sealant resistant to gas. 
This range can be used with Natural or 
LP/Propane gas. The range is shipped from the 
factory for use with natural gas.  
For LP/propane household installation, the 
appliance must be converted by the dealer, by a 
factory‐trained professional or by a qualified 
licensed plumber or gas service company.  
Gas conversion is important for safe and effective 
use of the appliance. It is the responsibility of the 
dealer and the owner of the range to perform the 
appropriate gas conversion following the 
directions of the manufacturer.   
THE GAS CONVERSION PROCEDURE IS 
DESCRIBED IN THIS MANUAL AND IN THE 
PACKAGE CONTAINING THE CONVERSION 
NOZZLES SHIPPED WITH EVERY RANGE. 
Please provide the service person with this 
manual before work is started on the range.  
 
WARNING! 
DO NOT USE AN OPEN FLAME WHEN CHECKING 
FOR LEAKS! 
Leak testing of the appliance shall be conducted 
according to the manufacturer's instructions. 
Before placing the oven into operation, always 
check for leaks with soapy water solution or 
other acceptable method.  
 
MANUAL SHUT‐OFF VALVE 
THIS VALVE IS NOT SHIPPED WITH THE 
APPLIANCE AND MUST BE SUPPLIED BY THE 
INSTALLER. 
The manual shut‐off valve must be installed in 
the gas service line between the gas hook‐up on 
the wall and the appliance inlet, in a position 
where it can be reached quickly in the event of an 
emergency.  
In Massachusetts: A 'T' handle type manual gas 
valve must be installed in the gas supply line to 
this appliance. 
 
FLEXIBLE CONNECTIONS 
In case of installation with flexible couplings 
and/or quick‐disconnect fittings, the installer 
must use a heavy‐duty, AGA design‐certified 
commercial flexible connector of at least 1/2" 
(1.3 cm) ID NPT (with suitable strain reliefs) in 
compliance with ANSI Z21.41 and Z21.69 
standards. 
In Massachusetts: The unit must be installed 
with a 36" (3‐foot) long flexible gas connector. 
In Canada: use CAN 1‐6.10‐88 metal connectors 
for gas appliances and CAN 1‐6.9 M79 quick 
disconnect device for use with gas fuel. 
 
PRESSURE TEST‐POINT STOPPER VALVE 
To avoid gas leaks, the pressure test‐point 
stopper valve and gasket supplied with the range 
must be installed on the gas fitting at the back of 
the range according to the diagram below.