Bertazzoni X365GGVCR Benutzerhandbuch

Seite von 39
 
17
Replace the nozzle using the conversion set 
supplied with the range or by a Bertazzoni 
authorized parts warehouse. Each nozzle has a 
number indicating its flow diameter printed on 
the body. Consult the table on page 20 for 
matching nozzles to burners.  
 
 
 
Adjust the primary airflow by loosening the screw 
P and setting the gap X in the Venturi cone to ½” 
(5/16” for natural gas).  
 
 
 
STEP 4: BROILER BURNER 
Loosen the screw and pull out the burner from its 
support.  
ATTENTION: pay extra attention to avoid damage 
to the igniter and thermocouple. 
 
 
Using a 7 mm [name of the tool] unscrew the 
nozzle. Replace the nozzle using the conversion 
set supplied with the range or by a Bertazzoni 
authorized parts warehouse. Each nozzle has a 
number indicating its flow diameter printed on 
the body. Consult the table on page 20 for 
matching nozzles to burners. 
 
 
Adjust the gap X by setting it to fully open 
position.