Vinotemp WM250-850SCU Benutzerhandbuch

Seite von 8
                                                                                
- 1 -
•  The WM25-85SFCD evaporator units shall be installed for ceiling mount 
with air supply on both sides and air return on the bottom. 
•  Supply and return air flow from the evaporator unit shall be unobstructed 
for at least 1 foot. 
•  There is a gravity drain line so that it can not be installed above the 
evaporator unit. Otherwise a condensation pump must be used. 
 
3. Air Sensor 
 
•  The air sensor can be located in the wine room or the return air area, but 
not the supply air area.   
 
4.  Refrigeration Piping and Charging 
 
NOTES: ALWAYS USE THE SUPERHEAT AND SUBCOOLING, 
PRESSURE READINGS TO CHARGE REFRIGERANT PROPERLY, THE 
LISTED CHARGES ARE FOR REFERENCE ONLY. 
 
•  The installation order starts from condensing unit (including the receiver), 
liquid line filter-drier, moisture-liquid indicator (sight glass), liquid line, 
evaporator unit (including liquid line solenoid valve and thermostatic 
expansion valve or automatic expansion valve), suction line, and returning 
to condensing unit.  
•  The subcooling at the condensing unit shall be around 10
°
F. The charge 
may be complete when there are no more bubbles forming in the sight 
glass. 
•  If equipped with a TXV, the evaporator superheat is set around 8-10 
°
F for 
a 10 
°
F TD system at factory.  
•  If equipped with an AXV, the valve is set around 38-40
°
F at factory and 
the superheat at the evaporator unit shall be around 9-18
°
F under low and 
high load at 75
°
F ambient temperature.  
•  Low side pressure: 33 psig 
•  High side pressure: 130 psig at 75 
°
F ambient temperature and 150 psig 
at 90 
°
F ambient temperature 
 
The line sizes and refrigerant charges are listed as follows. 
 
MODEL 
REFRIGERATION 
LINES 
LIQUID 
LINE 
SUCTION 
LINE 
DRAIN 
LINE 
CHARGE 
VINO-
2500SSD 
< 50 FT 
1/4" 
OD 
3/8” OD 
1/2” OD 
R134a/ 
20 OZ 
VINO-
4500SSD 
< 50 FT 
1/4" 
OD 
1/2” OD 
1/2” OD 
R134a/ 
26 OZ 
VINO-
6500SSD 
< 50 FT 
1/4" 
OD 
5/8” OD 
1/2” OD 
R134a/ 
32 OZ 
VINO-
8500SSD 
< 50 FT 
3/8" 
OD 
5/8” OD 
1/2” OD 
R134a/ 
38 OZ