Master Bilt CMICL-156 Benutzerhandbuch

Seite von 20
 
8
CAM FASTENERS 
 
 
NOTE:   When facing the interior of the wall panel, all vertical latch access holes should be on the left 
side of the panels. 
 
Before attempting to erect the walk-in, you should know how Master-Bilt cam-lock on some panels, it may be 
difficult to position the hex wrench as showing Figure #3, #4, and #5.  However, the locking procedure for all 
cam-locks will be as shown. 
Cam 
Wrench
Hook in Open 
Position
  
                Figure #3 
 
NOTE:  All cam-lock locking arms must be in the “open” position before attempting to lack panels 
together. 
 
Push panels together and turn cam-wretch ¼” turn clockwise. This will engage locking arm over locking pin.  
Continue to turn cam-wretch for ½” turn or until panels are fastened together securely. 
 
 
  
                    Figure # 4 
 
CAUTION:  Do not over-tighten cam fasteners. When the cam fastener tool stops, due to normal 
tightening, the fastener has done as much as it can. The panel will be tight and secure to the adjoining 
panel.