R
888 Porter Rd.  Muskegon, MI  49441  Phone: 231.798.8888  Fax: 231.798.4960  www.structuralconcepts.com 
CPC®  ESC3 SET POINT CHANGING INSTRUCTIONS 
Viewing and Changing the Temperature Set Point 
The temperature set point is the comparison point for the control temperature input. 
To change the set point value: 
 
1.  Press the Alarm key for 3 seconds, until the set point is displayed and blinking. 
2.  Press the compressor key or defrost key to raise/lower the value. 
3.  Press the Alarm key again to accept the new value. 
 
Changing Other Set Points 
There are two levels of set points in the ESC3.  The first level does not require a password to change 
(unless the buttons are locked out). The set points that can be changed in this manner are identified 
in table 1 as a USER set point  All other set points do require a password to change and are identi-
fied in table 2 as an OEM set point. 
Note: Table 2 can be obtained from OEM upon request. 
 
To change USER set points: 
1.  Press the alarm key and hold it until the letters PS are displayed.  
2.  Use the compressor and defrost keys to scroll through the codes for the different set points (see 
Table 1). 
3.  When the code is displayed for the set point you wish to change, press the alarm key. The value 
for that set point will be displayed.  
4.  Press the compressor or defrost key to change the value. 
5.  Press the alarm key to go back to the code. 
 
At this point you must press the alarm key to accept the change or press the compressor or defrost 
key to scroll to the next USER set point. To accept the changes, press and hold the alarm key until 
the display stops flashing.