B. Sequence of Operation
1. Sequence Cycles and Shutdown
The steps in the sequence are as outlined below. When power is supplied to CB, 
DM LEDs flash 3 times, then 
°
F LED turns on. Press the power button for 2 sec., the 
cabinet temperature and EvapFM icon turn on and EvapFM starts. 2-min. Comp delay 
timer starts. Comp icon flashes during the 2-min. Comp delay. When the 2-min. Comp 
delay timer terminates, Comp icon turns steady and Comp starts.
Note: • EvapFM de-energizes when door is opened.
• There is a Comp delay of 2 min. at startup.
• There is a minimum Comp run time of 3 min.
• There is a Comp delay of 2 min. after a power interruption.
Compressor Icon
Defrost Icon
Evaporator Fan Motor Icon
Power 
Button
"P" Set 
Button
"+" Up 
Button
"-" Down 
Button
Alarm Icon
°C
°F
°F LED
Cabinet Temperature LEDs
a) Refrigerator
• The °F and CT LEDs remain on throughout the sequence of operation.
• This appliance uses a time-initiated/time-terminated Comp off cycle defrost. The factory 
default defrost setting is once every 6 hours for 30 min.
• 6-hr. defrost timer starts the very first time CB is energized (factory testing). Defrost time 
is cumulative power on time, therefore time may vary between starting the appliance 
and the first defrost. After the first defrost, defrost can be monitored for activation every 
6 hours.
• Cabinet temperature is displayed during defrost.
1. Startup
EvapFM icon is on and Comp icon is flashing. EvapFM energizes. 2-min. Comp delay 
timer starts. Comp icon flashes until 2-min. Comp delay timer terminates.
2. Cool Down 
EvapFM icon is on and Comp icon turns steady. EvapFM continues. 2-min. Comp 
delay timer terminates. Comp energizes and 3-min. Comp run timer starts.
3. Cool Down Achieved 
EvapFM icon is on. CTh cools to setpoint (default 39°F). EvapFM continues. If Comp run 
time > 3-min., Comp icon turns off and Comp de-energizes. If Comp run time < 3-min., 
Comp continues until 3-min. Comp run timer terminates, then Comp icon turns off and 
Comp de-energizes.